#xizhen.airrtc.miac02
GERLSAIR 中央空调控制器(Mesh2.0)
urn:miot-spec-v2:device:thermostat:0000A031:xizhen-miac02:1:0000C822
Language
Service tree
Thermostat#2 · thermostat7 properties
Thermostat
#2 · thermostat
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Status
#2 · status
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Device Fault
#3 · fault
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Mode
#4 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Fan1Heat2Cool3Auto4Dry
Target Temperature
#5 · target-temperature
- Format
- float
- Access
- R / W / N
- Value
- 16 ~ 32, step 0.5 celsius
Fan Level
#6 · fan-level
- Format
- uint8
- Access
- R / W / N
- Value
- 0Auto1Breeze2Low3Medium4High5Powerful6Turbo7Max
Temperature
#7 · temperature
- Format
- float
- Access
- R / N
- Value
- -99999 ~ 99999, step 0.1 celsius
Environment#3 · environment2 properties
Environment
#3 · environment
Properties
Relative Humidity
#2 · relative-humidity
- Format
- uint8
- Access
- R / N
- Value
- 0 ~ 100, step 1 percentage
Temperature
#1 · temperature
- Format
- float
- Access
- R / N
- Value
- -99999 ~ 99999, step 0.5 celsius
Physical Controls Locked#10 · physical-controls-locked1 properties
Physical Controls Locked
#10 · physical-controls-locked
Properties
Physical Controls Locked
#1 · physical-controls-locked
- Format
- bool
- Access
- R / W / N
- Value
- —
Indicator Light#7 · indicator-light1 properties
Indicator Light
#7 · indicator-light
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Alarm#8 · alarm1 properties
Alarm
#8 · alarm
Properties
Alarm
#1 · alarm
- Format
- bool
- Access
- R / W / N
- Value
- —
Identify#11 · identify1 actions
Identify
#11 · identify
Actions
Identify
#1 · identify
Screen#9 · screen4 properties
Screen
#9 · screen
Properties
Brightness
#1 · brightness
- Format
- uint8
- Access
- R / W / N
- Value
- 1 ~ 100, step 1 percentage
Auto Screen Off Time
#2 · auto-screen-off-time
- Format
- uint8
- Access
- R / W / N
- Value
- 01 Minute12 Minutes25 Minutes3Never
Display State
#3 · display-state
- Format
- uint8
- Access
- R / W / N
- Value
- 0Screen Saver1Off Screen2Lower Brightness
Auto Screen Brightness
#4 · auto-screen-brightness
- Format
- uint8
- Access
- R / W / N
- Value
- 1 ~ 100, step 1 percentage
Air Conditioner Settings#4 · ac-settings10 properties
Air Conditioner Settings
#4 · ac-settings
Properties
Mode Support (Lower 8 bits: mode_support, Higher 8 bits: mode_support_now)
#1 · mode-support
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Fan Speed Support (Lower 8 bits: fan_max, Higher 8 bits: fan_mask)
#2 · fan-support
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Heating Mode Temperature Limits
#3 · heat-tset-limit
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Cooling Mode Temperature Limits
#4 · cool-tset-limit
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Auto Mode Temperature Limits
#5 · auto-tset-limit
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Fan Mode Temperature Limits
#6 · fan-tset-limit
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Dry Mode Temperature Limits
#7 · dry-tset-limit
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Additional Mode Support
#8 · aux-mode-support
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Additional Function Support Bits
#9 · aux-func-bit
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Airflow Direction Support
#10 · sw-max
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Air Conditioner Control Parameters#5 · ac-ctrl6 properties1 actions
Air Conditioner Control Parameters
#5 · ac-ctrl
Properties
Airflow Direction Control
#1 · sw
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Heating Mode Temperature Setting
#2 · heat-tset
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Cooling Mode Temperature Setting
#3 · cool-tset
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Auto Mode Temperature Setting
#4 · auto-tset
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Fan Mode Temperature Setting
#5 · fan-tset
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Dry Mode Temperature Setting
#6 · dry-tset
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Actions
Force Status Refresh
#1 · status-refresh
Module Information#6 · module-infomation9 properties
Module Information
#6 · module-infomation
Properties
AC Module Serial Number
#1 · ac-sn
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
IoT Module Serial Number
#2 · iot-sn
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
AC Module Hardware Version
#3 · ac-hv
- Format
- uint32
- Access
- N / R
- Value
- 0 ~ 4294967295, step 1
AC Module Software Version
#4 · ac-sv
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
IoT Module Hardware Version
#5 · iot-hv
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
IoT Module Software Version
#6 · iot-sv
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
Air Conditioner Brand
#7 · brand-id
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1
IoT Module Batch
#8 · iot-batch
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 4294967295, step 1
AC Module Batch
#9 · ac-batch
- Format
- uint32
- Access
- R / N
- Value