MIOT HomeMIOT Home
米家智能零冷水燃气热水器16L N1
#xiaomi.waterheater.m3

米家智能零冷水燃气热水器16L N1

urn:miot-spec-v2:device:water-heater:0000A02A:xiaomi-m3:1
Version v2 v1
Language
Service tree
Water Heater
#2 · water-heater
28 properties4 events

Properties

Device Fault
#1 · fault
Format
uint32
Access
R / N
Value
0 ~ 999999999, step 1
Target Temperature
#2 · target-temperature
Format
uint8
Access
R / W / N
Value
35 ~ 65, step 1 celsius
Temperature
#3 · temperature
Format
int8
Access
R / N
Value
-30 ~ 100, step 1 celsius
Mode
#4 · mode
Format
uint8
Access
R / W / N
Value
0Custom
1AI
2Baby Care
3Comfortable
4Pet Wash
5Kitchen
Status
#5 · status
Format
uint8
Access
R / N
Value
0Idle
1Using Water
2Pre-heat
3Bath Keep Warm
4Anti-icing
Switch Status
#6 · on
Format
bool
Access
R / W / N
Value
—
Bath Keep Warm
#7 · bath-keep-warm
Format
bool
Access
R / W / N
Value
—
Input Water Temperature
#8 · input-water-temperature
Format
int8
Access
R / N
Value
-30 ~ 100, step 1 celsius
Water Flow
#9 · water-flow
Format
float
Access
R / N
Value
0 ~ 255, step 0.1
Preheat
#10 · hot-water-recirculation
Format
bool
Access
R / W / N
Value
—
Preheat Time
#11 · preheat-time
Format
uint8
Access
R / W / N
Value
1 ~ 120, step 1 minutes
High Altitude Mode
#12 · high-altitude-mode
Format
uint8
Access
R / N
Value
0Normal
1High
Preheat Timer
#13 · preheat-timer
Format
string
Access
R / W / N
Value
—
ECO
#14 · eco
Format
bool
Access
R / W / N
Value
—
Water Control Preheat
#15 · water-control-preheat
Format
bool
Access
R / W / N
Value
—
Rapid Preheat
#16 · rapid-preheat
Format
bool
Access
R / W / N
Value
—
Intelligent Preheat
#17 · intelligent-preheat
Format
bool
Access
R / W / N
Value
—
Anti Icing Status
#18 · anti-icing-status
Format
uint8
Access
R / N
Value
0Normal
1Electric Auxiliary
2Pump Circulation
3Ignition Heating
Enhanced Anti Icing
#19 · enhanced-anti-icing
Format
bool
Access
R / W / N
Value
—
Boost Mode
#20 · boost-mode
Format
uint8
Access
R / W / N
Value
0Standard
1AI Boost
Boost Level
#21 · boost-level
Format
uint8
Access
R / W / N
Value
0Level1
1Level2
2Level3
Boost
#22 · boost
Format
bool
Access
R / W / N
Value
—
Eco Study Status
#23 · eco-study-status
Format
uint8
Access
R / N
Value
0Idle
1Studying
2Studying Complete
3Studying Failed
Ventilation
#24 · ventilation
Format
bool
Access
R / W / N
Value
—
Ventilation Time
#25 · ventilation-time
Format
uint8
Access
R / W / N
Value
1 ~ 10, step 1 minutes
Water Pump Volt
#26 · water-pump-volt
Format
float
Access
R / N
Value
0 ~ 5, step 0.1
Cloud- Preheater
#27 · cloud-preheater
Format
bool
Access
R / W / N
Value
—
Preheat Timer
#28 · preheat-timer
Format
string
Access
R / W / N
Value
—

Events

Preheat Complete
#1 · preheat-complete
Wash Overtime
#2 · wash-overtime
Using Water
#3 · using-water
Stop Using Water
#4 · stop-using-water
Screen
#3 · screen
1 properties

Properties

Auto Screen Off Time
#6 · auto-screen-off-time
Format
uint8
Access
R / W / N
Value
1 ~ 120, step 1
Usage Report
#4 · usage-report
4 properties1 events

Properties

Water Consumption
#1 · water-consumption
Format
float
Access
R / N
Value
0 ~ 999999, step 0.1
Gas Consumption
#2 · gas-consumption
Format
float
Access
R / N
Value
0 ~ 9999999, step 0.001
Used Time
#3 · used-time
Format
uint32
Access
R / N
Value
0 ~ 99999, step 1 seconds
Temperature
#4 · temperature
Format
uint8
Access
R / N
Value
30 ~ 100, step 1 celsius

Events

Usage Record
#1 · usage-record
Arguments
#1Water Consumptionfloat#2Gas Consumptionfloat#3Used Timeuint32#4Temperatureuint8