浦安达三相智能保护开关
#iot.switch.padwb1

浦安达三相智能保护开关

urn:miot-spec-v2:device:switch:0000A003:iot-padwb1:2
Version v2 v1
Language
Service tree
Switch
#2 · switch
3 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Device Fault
#5 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Leakage Alarm
2Phase Deficiency Alarm
Default Power On State
#8 · default-power-on-state
Format
uint8
Access
R / W / N
Value
0Off
1On
2Default
Power Consumption
#3 · power-consumption
1 properties

Properties

Power Consumption
#1 · power-consumption
Format
float
Access
R / N
Value
0 ~ 65535, step 0.1 kWh
custom
#5 · custom
29 properties

Properties

a-electric-current
#1 · a-electric-current
Format
float
Access
N / R
Value
0 ~ 99999, step 0.1
a-power
#2 · a-power
Format
int32
Access
N / R
Value
0 ~ 99999, step 1 watt
a-voltage
#3 · a-voltage
Format
int32
Access
R / N
Value
0 ~ 99999, step 1
b-electric-current
#5 · b-electric-current
Format
float
Access
N / R
Value
0 ~ 99999, step 0.1
b-power
#6 · b-power
Format
int32
Access
N / R
Value
0 ~ 99999, step 1 watt
b-voltage
#7 · b-voltage
Format
int32
Access
N / R
Value
0 ~ 99999, step 1
c-electric-current
#9 · c-electric-current
Format
float
Access
N / R
Value
0 ~ 99999, step 0.1
c-power
#10 · c-power
Format
int32
Access
N / R
Value
0 ~ 99999, step 1 watt
c-voltage
#11 · c-voltage
Format
int32
Access
N / R
Value
0 ~ 99999, step 1
a-temperature
#13 · a-temp
Format
float
Access
N / R
Value
-500 ~ 500, step 0.1 celsius
b-temperature
#14 · b-temp
Format
float
Access
N / R
Value
-500 ~ 500, step 0.1 celsius
c-temperature
#15 · c-temp
Format
float
Access
N / R
Value
-500 ~ 500, step 0.1 celsius
a-fault
#16 · a-fault
Format
uint8
Access
N / R
Value
0Normal
2A-phase Overcurrent Alarm
3A-phase Overvoltage Alarm
4A-phase Undervoltage Alarm
5A-phase Overtemperature Alarm
b-fault
#17 · b-fault
Format
uint8
Access
N / R
Value
0Normal
2B-phase Overcurrent Alarm
3B-phase Overvoltage Alarm
4B-phase Undervoltage Alarm
5B-phase Overtemperature Alarm
c-fault
#18 · c-fault
Format
uint8
Access
N / R
Value
0Normal
2C-phase Overcurrent Alarm
3C-phase Overvoltage Alarm
4C-phase Undervoltage Alarm
5C-phase Overtemperature Alarm
self-check
#19 · self-check
Format
bool
Access
R / N / W
Value
—
leak-set
#20 · leak-set
Format
string
Access
R / N / W
Value
—
leak-switch
#21 · leak-switch
Format
bool
Access
R / N / W
Value
—
voice-switch
#22 · voice-switch
Format
bool
Access
R / N / W
Value
—
over-electric-set
#23 · over-electric-set
Format
int16
Access
R / N / W
Value
1 ~ 100, step 1
lack-voltage-set
#24 · lack-voltage-set
Format
int16
Access
R / N / W
Value
90 ~ 210, step 1
delay-set
#28 · delay-set
Format
int16
Access
R / N / W
Value
1 ~ 60, step 1
timer-set
#29 · timer-set
Format
string
Access
R / N / W
Value
—
close-temp-set
#30 · close-temp-set
Format
int16
Access
R / N / W
Value
60 ~ 100, step 1 celsius
over-voltage-set
#31 · over-voltage-set
Format
int16
Access
R / N / W
Value
230 ~ 320, step 1
alert-temp-set
#32 · alert-temp-set
Format
int8
Access
R / N / W
Value
50 ~ 90, step 1 celsius
setting-tips
#33 · setting-tips
Format
string
Access
R / N
Value
—
trigger reporting
#34 · trigger-reporting
Format
uint8
Access
W
Value
1Trigger
#35 · delay-set-switch
Format
bool
Access
R / N / W
Value
—