MIOT HomeMIOT Home
子擎存在传感器 Lite
#izq.sensor_occupy.24

子擎存在传感器 Lite

urn:miot-spec-v2:device:occupancy-sensor:0000A0BF:izq-24:3:0000C824
Version v4 v3 v2 v1
Language
Service tree
Global
#2 · occupancy-sensor
7 properties1 events

Properties

Occupy
#1 · occupancy-status
Format
uint8
Access
R / N
Value
0No One
1Has One
2Motion Moving
3Motion Static
4Approaching
5Move Away
241Confirming
242Checking
No One Determine Time
#2 · no-one-determine-time
Format
uint16
Access
R / W / N
Value
0 ~ 10000, step 1 seconds
Show Duration
#3 · has-someone-duration
Format
uint8
Access
R / N
Value
0 ~ 255, step 1 minutes
No Show Duration
#4 · no-one-duration
Format
uint8
Access
R / N
Value
0 ~ 255, step 1 minutes
Illumination
#5 · illumination
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1 lux
Distance,Continuous trigger mode valid only
#6 · distance
Format
uint16
Access
R / N
Value
0 ~ 1000, step 1 cm
Enable Sense,Turning off will disable radar and related automation
#7 · enable-switch
Format
bool
Access
R / W / N
Value
—

Events

Device Be Reset
#1 · device-be-reset
Range 1
#11 · occupancy-sensor
7 properties

Properties

Occupy
#1 · occupancy-status
Format
uint8
Access
R / N
Value
0No One
1Has One
No One Determine Time
#2 · no-one-determine-time
Format
uint16
Access
R / W / N
Value
10 ~ 3600, step 1 seconds
Show Duration
#3 · has-someone-duration
Format
uint8
Access
R / N
Value
0Unknown
11 Min Has People
22 Min Has People
55 Min Has People
No Show Duration
#4 · no-one-duration
Format
uint8
Access
R / N
Value
0Unknown
22 Min No One
55 Min No One
1010 Min No One
3030 Min No One
Range Begin Distance
#5 · detection-distance
Format
float
Access
R / W / N
Value
0 ~ 8, step 0.1 m
Range End Distance
#6 · detection-distance
Format
float
Access
R / W / N
Value
0 ~ 8, step 0.1 m
Enable
#7 · enable-switch
Format
bool
Access
R / W / N
Value
—
Range 2
#12 · occupancy-sensor
7 properties

Properties

Occupy
#1 · occupancy-status
Format
uint8
Access
R / N
Value
0No One
1Has One
No One Determine Time
#2 · no-one-determine-time
Format
uint16
Access
R / W / N
Value
10 ~ 3600, step 1 seconds
Show Duration
#3 · has-someone-duration
Format
uint8
Access
R / N
Value
0Unknown
11 Min Has People
22 Min Has People
55 Min Has People
No Show Duration
#4 · no-one-duration
Format
uint8
Access
R / N
Value
0Unknown
22 Min No One
55 Min No One
1010 Min No One
3030 Min No One
Range Begin Distance
#5 · detection-distance
Format
float
Access
R / W / N
Value
0 ~ 8, step 0.1 m
Range End Distance
#6 · detection-distance
Format
float
Access
R / W / N
Value
0 ~ 8, step 0.1 m
Enable
#7 · enable-switch
Format
bool
Access
R / W / N
Value
—
Range 3
#13 · occupancy-sensor
7 properties

Properties

Occupy
#1 · occupancy-status
Format
uint8
Access
R / N
Value
0No One
1Has One
No One Determine Time
#2 · no-one-determine-time
Format
uint16
Access
R / W / N
Value
10 ~ 3600, step 1 seconds
Show Duration
#3 · has-someone-duration
Format
uint8
Access
R / N
Value
0Unknown
11 Min Has People
22 Min Has People
55 Min Has People
No Show Duration
#4 · no-one-duration
Format
uint8
Access
R / N
Value
0Unknown
22 Min No One
55 Min No One
1010 Min No One
3030 Min No One
Range Begin Distance
#5 · detection-distance
Format
float
Access
R / W / N
Value
0 ~ 8, step 0.1 m
Range End Distance
#6 · detection-distance
Format
float
Access
R / W / N
Value
0 ~ 8, step 0.1 m
Enable
#7 · enable-switch
Format
bool
Access
R / W / N
Value
—
Occupancy Service
#3 · occupancy-config
17 properties6 actions2 events

Properties

LED
#1 · led-enable
Format
bool
Access
R / W / N
Value
—
Detection Distance
#2 · detect-range
Format
float
Access
N / R / W
Value
0 ~ 8, step 0.01 metre
Fusion Detection,Reduces false detects, may slow detection response
#3 · pir-enable
Format
bool
Access
N / R / W
Value
—
Deprecated
#4 · device-params
Format
uint32
Access
N / R / W
Value
0 ~ 4294967295, step 1
Motion Confirm Time,Continuous motion beyond set time confirms occupancy.
#5 · enterin-confirm-time
Format
uint8
Access
N / R / W
Value
0 ~ 60, step 1 seconds
Fault
#6 · fault
Format
uint8
Access
R / N
Value
0 ~ 255, step 1
Custom No Show Duration State
#7 · cust-blur-dura
Format
uint8
Access
R / N
Value
0 ~ 60, step 1 seconds
Custom Show Duration State
#8 · cust-show-dura
Format
uint8
Access
R / N
Value
0 ~ 60, step 1 seconds
Custom No Show Duration
#9 · cust-blur-dura-cfg
Format
uint8
Access
R / W / N
Value
0 ~ 60, step 1 seconds
Custom Show Duration
#10 · cust-show-dura-cfg
Format
uint8
Access
R / W / N
Value
0 ~ 60, step 1 seconds
Customized Spatial Sense
#11 · spatial-learn-status
Format
uint8
Access
R / N
Value
0 ~ 255, step 1
Spatial Learning Result
#12 · spatial-learn-result
Format
uint8
Access
Value
0 ~ 255, step 1
Lux Sensor,Lux Sensor at off mode limits bandwidth and related automation.
#13 · illumination-enable
Format
bool
Access
R / W / N
Value
—
Motion Sense,Enabling it allows more automation options but uses more bandwidth.
#14 · motion-sense
Format
bool
Access
R / W / N
Value
—
Automation Trigger Mode
#15 · distance-mode
Format
uint8
Access
R / W / N
Value
0Continuous Trigger,Monitors distance with possible trigger delays
1Range Trigger,Up to 3 zones with instant triggers & no one determine timer
2Global Trigger,Detect human occupancy only, most suitable for daily use
Auto Ignore Fixed Noise (Beta),Sensor can auto ignore noise for better accuracy.
#16 · auto-spatial-learn
Format
bool
Access
R / W / N
Value
—
Manual Turn-Off Light Fast-Check
#17 · hand-light-off-check
Format
bool
Access
R / W / N
Value
—

Actions

Toggle LED
#1 · toggle-led
Request Distance Period
#2 · req-distance-period
Find Device
#3 · find-device
Spatial Learning Start
#4 · spatial-learn-start
Spatial Learning Reset
#5 · spatial-learn-reset
Reset Occupy Status
#6 · reset-occupy-status

Events

Device Params Updated
#1 · device-param-changed
Arguments
#4Deprecateduint32
Spatial Learning Result
#2 · spatial-learn-result
Arguments
#12Spatial Learning Resultuint8
Offline Automation
#4 · stepsync-service
4 properties2 actions

Properties

When Show Then LBRC Do,LeMesh(R)
#1 · when-show-lbrc-do
Format
uint8
Access
R / W / N
Value
0Do Nothing
1Turn On
2Turn Off
When No Show Then LBRC Do
#2 · when-blur-lbrc-do
Format
uint8
Access
R / W / N
Value
0Do Nothing
1Turn On
2Turn Off
When Show & Lux Is Then LBRC Do
#3 · when-show-lbrc-luxr
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
When No Show & Lux Is Then LBRC Do
#4 · when-blur-lbrc-luxr
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1

Actions

Request LBRC Bind
#1 · lbrc-req-bind
Want to unbind?
#2 · lbrc-req-unbind
stdio
#5 · stdio
1 properties

Properties

payload
#1 · payload
Format
string
Access
Value
—