MIOT HomeMIOT Home
米家冰箱Pro 600L十字 自动制冰
#midjd.fridge.bs60s

米家冰箱Pro 600L十字 自动制冰

urn:miot-spec-v2:device:fridge:0000A00F:midjd-bs60s:1:0000D01E
Version v2 v1
Language
Service tree
Fridge
#2 · fridge
4 properties

Properties

Device Fault
#1 · fault
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
Door Not Close Remind
#3 · door-not-close-remind
Format
uint8
Access
R / N
Value
0 ~ 255, step 1
Door Not Close Name
#4 · door-not-close-name
Format
uint32
Access
Value
1Refrigerator Left Door
2Refrigerator Right Door
3Freezing Left Door
4Freezing Right Door
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Manual
1Smart
2Quick Cooling
3Quick Frozen
Fridge
#3 · fridge-chamber
2 properties

Properties

Temperature
#1 · temperature
Format
int8
Access
R / N
Value
-50 ~ 100, step 1
Target Temperature
#2 · target-temperature
Format
uint8
Access
R / W / N
Value
2 ~ 8, step 1
Freezer
#4 · fridge-chamber
3 properties

Properties

Temperature
#1 · temperature
Format
int8
Access
R / N
Value
-50 ~ 100, step 1
Target Temperature
#2 · target-temperature
Format
int8
Access
R / W / N
Value
-24 ~ -16, step 1
Quick Frozen Temperature
#3 · quick-frozen-temperature
Format
int8
Access
Value
-30 ~ -16, step 1 celsius
Change Cabin
#6 · fridge-chamber
2 properties

Properties

Temperature
#1 · temperature
Format
int8
Access
R / N
Value
-50 ~ 100, step 1
Mode
#3 · mode
Format
uint8
Access
R / W / N
Value
0Dried Foods
1Maternal-infant Products
2Zero Degree
Self Check
#14 · self-check
1 properties

Properties

Self Check Results
#1 · self-check-results
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
Ice Maker
#8 · ice-maker
4 properties1 events

Properties

Mode
#1 · mode
Format
uint8
Access
R / W / N
Value
0Normal
2Clean
3Stop
Ice Maker Status
#3 · ice-maker-status
Format
uint8
Access
R / W / N
Value
0Normal
1Full Of Ice
2Lack Of Water
3Full Of Ice And Lack Of Water
Ice Maker Order
#4 · ice-maker-order
Format
uint32
Access
R / W / N
Value
0 ~ 10080, step 1 minutes
Ice Maker Order Switch
#6 · ice-maker-order-switch
Format
bool
Access
R / W / N
Value
—

Events

Clean Complete
#1 · clean-complete
fridge-reset
#7 · fridge-reset
1 actions1 events

Actions

reset
#1 · reset

Events

reset
#1 · reset
fridge-run-status
#10 · fridge-run-status
43 properties

Properties

#1 · defrost-status
Format
uint8
Access
N
Value
0Off
1On
defrost-temperature
#2 · defrost-temperature
Format
int8
Access
N
Value
-50 ~ 100, step 1 celsius
#3 · refrigerating-damper
Format
uint8
Access
N
Value
0Close
1Open
freezing-fan
#4 · freezing-fan
Format
uint8
Access
N
Value
0 ~ 255, step 1
#5 · compressor-speed
Format
uint16
Access
N
Value
0 ~ 10000, step 1
condensation-fan
#6 · condensation-fan
Format
uint8
Access
N
Value
0 ~ 255, step 1
#7 · change-damper
Format
uint8
Access
N
Value
0Close
1Open
#8 · mini-change-damper
Format
uint8
Access
N
Value
0Close
1Open
#9 · environment-temp
Format
int8
Access
N
Value
-50 ~ 100, step 1 celsius
#10 · environment-humidity
Format
uint8
Access
N
Value
0 ~ 100, step 1 percentage
#11 · door-status
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#12 · inverter-fault
Format
uint8
Access
N
Value
0 ~ 255, step 1
#13 · system-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#14 · defrost-reason
Format
uint8
Access
N
Value
0 ~ 255, step 1
#15 · defrost-step
Format
uint8
Access
N
Value
0 ~ 255, step 1
#16 · compressor-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#17 · freezer-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#18 · room-freezer-state
Format
uint8
Access
N
Value
0 ~ 255, step 1
#19 · ref-fan-level
Format
uint8
Access
N
Value
0 ~ 255, step 1
comp-feedback-freq
#20 · comp-feedback-freq
Format
uint16
Access
N
Value
0 ~ 65535, step 1
comp-feedback-power
#21 · comp-feedback-power
Format
uint16
Access
N
Value
0 ~ 65535, step 1
comp-feedback-vol
#22 · comp-feedback-vol
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#23 · total-runtime
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#24 · comp-total-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#25 · com-runtime
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#26 · defrost-pre-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#27 · frz-heater-on-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#28 · supermode-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#29 · defrost-runtime
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#30 · heater-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#31 · ice-load-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#32 · ice-making-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#33 · ice-target-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#34 · ice-run-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#35 · ice-current-time
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#36 · error-query
Format
uint32
Access
N
Value
0 ~ 4294967295, step 1
#37 · valve-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#38 · ref-open-times
Format
uint8
Access
N
Value
0 ~ 255, step 1
#39 · ref-open-timer
Format
uint16
Access
N
Value
0 ~ 65535, step 1
#40 · frz-open-times
Format
uint8
Access
N
Value
0 ~ 255, step 1
#41 · frz-open-timer
Format
uint16
Access
N
Value
0 ~ 65535, step 1 minutes
#43 · ref-def-snr
Format
int8
Access
N
Value
-50 ~ 100, step 1
#47 · refdefrost-status
Format
bool
Access
N
Value
—
custom-service
#13 · custom-service
2 properties

Properties

#10 · grid-defrost
Format
bool
Access
R / N / W
Value
—
#11 · grid-forceload
Format
uint8
Access
R / N / W
Value
0Normal
1Delay
2Reduce
remote-maintenance
#16 · remote-maintenance
8 properties

Properties

#1 · parameter-one
Format
string
Access
R / N / W
Value
—
#2 · parameter-two
Format
string
Access
R / N / W
Value
—
#3 · parameter-three
Format
string
Access
R / N / W
Value
—
#4 · parameter-four
Format
string
Access
R / N / W
Value
—
#5 · parameter-five
Format
string
Access
R / N / W
Value
—
#6 · parameter-six
Format
string
Access
R / N / W
Value
—
#7 · parameter-seven
Format
string
Access
R / N / W
Value
—
#8 · parameter-eight
Format
string
Access
R / N / W
Value
—