MIOT HomeMIOT Home
宅鲸净化加湿器A2Pro
#zjaupu.humidifier.a2s

宅鲸净化加湿器A2Pro

urn:miot-spec-v2:device:humidifier:0000A00E:zjaupu-a2s:1
Language
Service tree
Humidifier
#2 · humidifier
9 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Device Fault
#2 · fault
Format
uint8
Access
R / N
Value
0No Faults
6Eb:The communication between the main control module and the power module is fau
7EC:The water level monitoring board communication is faulty
Mode
#3 · mode
Format
uint8
Access
R / W / N
Value
0Constant Humidity
1Strong
2Sleep
3Adjust Speed
4Humidity
Fan Level
#5 · fan-level
Format
uint8
Access
R / W / N
Value
1 ~ 5, step 1
Target Humidity
#6 · target-humidity
Format
uint8
Access
R / W / N
Value
30 ~ 70, step 1 percentage
Water Level
#7 · water-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Status
#8 · status
Format
uint8
Access
R / N
Value
2Busy
3Stop
Overwet Protect
#9 · overwet-protect
Format
bool
Access
R / W / N
Value
—
Status
#10 · status
Format
uint8
Access
R / N
Value
0Waiting
1Working
2Wait Degermi
3Start Up
Environment
#3 · environment
2 properties

Properties

Relative Humidity
#1 · relative-humidity
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Temperature
#2 · temperature
Format
float
Access
R / N
Value
-30 ~ 100, step 1 celsius
Filter
#4 · filter
4 properties2 actions

Properties

Filter Life Level
#1 · filter-life-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Filter Used Time
#2 · filter-used-time
Format
uint16
Access
R / N
Value
0 ~ 10000, step 1 hours
Filter Life Level
#3 · filter-life-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Filter Used Time
#4 · filter-used-time
Format
uint16
Access
R / N
Value
0 ~ 10000, step 1 hours

Actions

Reset Filter Life
#1 · reset-filter-life
Reset Filter Life
#2 · reset-filter-life
Alarm
#5 · alarm
1 properties

Properties

Alarm
#1 · alarm
Format
bool
Access
R / W / N
Value
—
Countdown
#6 · countdown
1 properties

Properties

Countdown Time
#1 · countdown-time
Format
uint32
Access
R / W / N
Value
0 ~ 720, step 1 minutes
Physical Control Locked
#8 · physical-controls-locked
1 properties

Properties

Physical Control Locked
#11 · physical-controls-locked
Format
bool
Access
R / W / N
Value
—
Screen
#9 · screen
1 properties

Properties

Auto Screen Off
#4 · auto-screen-off
Format
bool
Access
R / W / N
Value
—
Remaining Configuration
#7 · other
5 properties

Properties

Add Water Switch
#2 · add-water
Format
bool
Access
R / N / W
Value
—
NBSS Switch
#3 · nbss-switch
Format
bool
Access
R / N
Value
—
Electrolytic Water Level
#4 · elect-level
Format
uint8
Access
R / N / W
Value
0Low
1Med
2High
Lack Water Warning
#5 · water-fault
Format
uint8
Access
R / N
Value
0Normal
1Start Lack Water
3Work-lack-water
Water change reminder
#6 · push-remind
Format
uint8
Access
R / N
Value
0Normal
1Water Remind
2Wash Remind