MIOT HomeMIOT Home
YKCN 智慧用电电源 TTDZ-63A
#ykcn.valve.01

YKCN 智慧用电电源 TTDZ-63A

urn:miot-spec-v2:device:electronic-valve:0000A0A7:ykcn-01:1
Language
Service tree
Electronic Valve
#2 · electronic-valve
5 properties

Properties

Valve Switch
#1 · valve-switch
Format
bool
Access
R / W / N
Value
—
Target Water Level
#2 · target-water-level
Format
uint8
Access
R / W / N
Value
1Level1
Device Fault
#5 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Too High Power
3Overcurrent Alarm
4Overvoltage Alarm
5Under-voltage Alarm
2High-temperature Alarm
6Leakage Alarm
Mode
#8 · mode
Format
uint8
Access
R / W / N
Value
0Off
1On
Switch Status
#3 · on
Format
bool
Access
R / W / N
Value
—
Power Consumption
#3 · power-consumption
4 properties

Properties

Power Consumption
#1 · power-consumption
Format
uint32
Access
R / N
Value
0 ~ 99999999, step 1 kWh
Electric Current
#2 · electric-current
Format
uint32
Access
R / N
Value
0 ~ 16777216, step 1
Voltage
#3 · voltage
Format
uint32
Access
R / N
Value
0 ~ 65535, step 1
Electric Power
#6 · electric-power
Format
int32
Access
R / N
Value
0 ~ 16777216, step 1 watt
Alarm setting
#4 · fault-setting
12 properties

Properties

Overpower - The value is set
#1 · electric-alarm
Format
uint8
Access
R / N / W
Value
1 ~ 23, step 1 watt
Setting the power overhigh alarm
#2 · electric-alarm-set
Format
bool
Access
R / N / W
Value
—
high-temperature-set
#3 · high-temperature-set
Format
uint8
Access
W / R / N
Value
40 ~ 150, step 1 celsius
#4 · temperature-alarm
Format
bool
Access
R / N / W
Value
—
Overcurrent alarm - Threshold setting
#5 · overcurrent-alarm
Format
uint8
Access
R / N / W
Value
1 ~ 80, step 1 A
Setting the overcurrent alarm
#6 · overcurrent-set
Format
bool
Access
R / N / W
Value
—
Overvoltage alarm - Threshold setting
#7 · overvoltage-alarm
Format
uint16
Access
R / N / W
Value
220 ~ 300, step 1 V
Setting an overvoltage alarm
#8 · overvoltage-set
Format
bool
Access
R / N / W
Value
—
Undervoltage alarm - Min Value setting
#9 · undervoltage-alarm
Format
uint8
Access
R / N / W
Value
90 ~ 220, step 1 V
Setting the undervoltage alarm
#10 · undervoltage-set
Format
bool
Access
R / N / W
Value
—
eakage-alarm
#12 · eakage-alarm
Format
uint8
Access
W / R / N
Value
5 ~ 99, step 1 mA
#13 · electric-leakage-set
Format
bool
Access
W / R / N
Value
—
custom
#5 · custom
6 properties1 actions

Properties

#1 · temperature-alarm
Format
bool
Access
R / W / N
Value
—
#2 · child-lock
Format
bool
Access
R / N / W
Value
—
#4 · beep-switch
Format
bool
Access
R / N / W
Value
—
#5 · set-time-protection
Format
string
Access
R / N / W
Value
—
#13 · temperature
Format
float
Access
R / N
Value
-20 ~ 100, step 1 celsius
#14 · loudian-dianliu
Format
uint32
Access
R / N
Value
0 ~ 999, step 1 A

Actions

zijian
#1 · zijian