MIOT HomeMIOT Home
Xiaomi Smart Water Dispenser (Hot and Cold)
#xiaomi.ysj.v2

Xiaomi Smart Water Dispenser (Hot and Cold)

urn:miot-spec-v2:device:water-dispenser:0000A0A1:xiaomi-v2:1
Language
Service tree
Water Dispenser
#2 · water-dispenser
4 properties

Properties

Device Fault
#1 · fault
Format
uint32
Access
R / N
Value
0 ~ 1000000000, step 1
Status
#2 · status
Format
uint8
Access
R / N
Value
0PowerOff
1Standby
2WaterOut
3Icing
4Rinsing
5Rinsed
6DirtyOut
7Lacing
Room temp water
#3 · temperature
Format
int32
Access
R / N
Value
-30 ~ 100, step 1 celsius
Water output temperature
#4 · target-temperature
Format
uint32
Access
R / W / N
Value
0 ~ 100, step 1 celsius
Total Dissolved Solids Sensor
#3 · tds-sensor
Water Use Details
#5 · water-use-details
3 properties1 events

Properties

Water Production Time
#1 · water-production-time
Format
uint32
Access
R / N
Value
0 ~ 1000000000, step 1 seconds
Pure Water Output
#2 · pure-water-output
Format
uint32
Access
R / N
Value
0 ~ 1000000000, step 1
Temperature
#3 · temperature
Format
int32
Access
R / N
Value
-30 ~ 100, step 1 celsius

Events

Water Production Completed
#2 · water-production-completed
Arguments
#1Water Production Timeuint32#2Pure Water Outputuint32#3Temperatureint32
custom
#4 · custom
12 properties2 actions2 events

Properties

#1 · icing
Format
bool
Access
R / N / W
Value
—
#2 · current-mode-flow
Format
string
Access
R / N / W
Value
—
#3 · current-mode-temp
Format
string
Access
R / N / W
Value
—
#4 · mode
Format
uint16
Access
R / N / W
Value
1Ice
2Normal
3Warm
4Boiling
#5 · rinse-status
Format
uint16
Access
R / N / W
Value
0Idle
1Rinsing
2Rinse-Terminal
3Rinse-Complete
#6 · rinse-progress
Format
uint16
Access
R / N
Value
0 ~ 100, step 1 percentage
#7 · child-lock
Format
bool
Access
R / N / W
Value
—
#8 · drink-remind
Format
bool
Access
R / N / W
Value
—
#9 · switch-button
Format
bool
Access
R / N / W
Value
—
#10 · store-timeout
Format
uint16
Access
R / N
Value
0 ~ 36, step 1 hours
#11 · whether-have-water
Format
uint8
Access
R / N
Value
0No
1Yes
#12 · buzzer-enable
Format
bool
Access
R / N / W
Value
—

Actions

set-flow
#1 · set-flow
Input
#2string#4uint16
set-temp
#2 · set-temp
Input
#3string#4uint16

Events

drink-notify
#1 · drink-notify
line-sterilization
#2 · line-sterilization
debug
#6 · debug
4 properties

Properties

#1 · water-lv
Format
uint8
Access
R / N
Value
0 ~ 255, step 1
#2 · water-out-pump
Format
uint16
Access
R / N / W
Value
0 ~ 2400, step 1
#3 · output-water-temp
Format
int32
Access
R / N
Value
-300 ~ 2000, step 1
#4 · cool-temp
Format
int32
Access
R / N
Value
-300 ~ 2000, step 1
local-timing
#7 · local-timing
6 properties

Properties

#1 · scene-sequence
Format
string
Access
R / N / W
Value
—
#2 · scene-one
Format
string
Access
R / N / W
Value
—
#3 · scene-two
Format
string
Access
R / N / W
Value
—
#4 · scene-three
Format
string
Access
R / N / W
Value
—
#5 · scene-four
Format
string
Access
R / N / W
Value
—
#6 · scene-five
Format
string
Access
R / N / W
Value
—