#viomi.washer.w1
云米互联网壁挂洗衣机 小新
urn:miot-spec-v2:device:washer:0000A01F:viomi-w1:1
Language
Service tree
Washer#2 · washer8 properties2 actions
Washer
#2 · washer
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Status
#2 · status
- Format
- uint8
- Access
- R / N
- Value
- 0Off1Idle4Delay7Busy9Busy11Busy17Idle25Busy26Paused27Fault
Mode
#3 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Golden Wash4Spin16Antibacterial22Rinse Spin23Drum Clean29Boil Wash31Delicate Wash36New Cloth37Socks38Bra39Towel Bowash40Gloves13Underwear
Device Fault
#4 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No faults1E1 Water Inlet Timeout2E2 Drainage Timeout, The Water Did Not Empty In 6 Mins3E3 Locking And Unlocking Error4E4 Overflow5E5 Water Level Sensor Error And The Frequency No Change In 6 Mins6E6 Water Heating Error, No Heating, Changed Less Than 2 Degrees In 8 Mins7E7 Error Water Heating, High Temperature, Over 90 Degrees, Below 0 Degrees8The Communication Of The Main Board Of The E9 Display Board Is Error, Please Contact After Sales9Unb Uneven Clothing Distribution10F1 IPM Over Temperature11F2 Overcurrent Protection12F3 Motor Phase Loss13F4 Motor Locked Rotor14F5 Inverter Over Voltage15F6 Inverter Under Voltage16F7 Converter Eeppom Error17Communication Of F8 Frequency Converter Board Error18F9 Motor Speed Signal Lost19F10 No Model Command Or Abnormal Restart Of Frequency Converter Board20E41 During Drying, The Water Level In The Cylinder Exceeds The Limit Value21E61 Drying And Heating Temperature Is Error, Abnormally High, Over 120℃22Stop, The Door Remains Locked. Non Recoverable23NTC Temperature At The Inlet Of E63 Drying Channel Error24E64 Startup, Fan Detection Abnormal25U1 Automatic Delivery Box Is Not Pushed In Place, Please Check26Zero Crossing Detection Error, Please Contact After Sales27Main Control Panel Relay Error,please Contact After Sales28Farmware Error,please Contact After Sales29Sensor Work Error
Left Time
#5 · left-time
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65535, step 1 minutes
Target Temperature
#6 · target-temperature
- Format
- uint8
- Access
- R / W / N
- Value
- 0Normal Temperature3030℃4040℃6060℃8080℃
Spin Speed
#7 · spin-speed
- Format
- uint16
- Access
- R / W / N
- Value
- 400400 RPM600600 RPM700700 RPM
Rinsh Times
#9 · rinsh-times
- Format
- uint8
- Access
- R / W / N
- Value
- 11 Time22 Time33 Time44 Time
Actions
Start Wash
#1 · start-wash
Pause
#2 · pause
Physical Control Locked#3 · physical-controls-locked1 properties
Physical Control Locked
#3 · physical-controls-locked
Properties
Physical Control Locked
#1 · physical-controls-locked
- Format
- bool
- Access
- R / W / N
- Value
- —
User Define Property#4 · consumables1 properties
User Define Property
#4 · consumables
Properties
Delay Time
#10 · prepare-time
- Format
- uint16
- Access
- R / N / W
- Value
- 0 ~ 1440, step 1 minutes