#topwit.switch.rzw25
智能开关单火二位(Mesh)
urn:miot-spec-v2:device:switch:0000A003:topwit-rzw25:1:0000C809
Language
Service tree
Left switch#2 · switch2 properties1 actions
Left switch
#2 · switch
Properties
Left switch
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Mode
#2 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Wired And Wireless1Wireless
Actions
Toggle
#1 · toggle
Right switch#3 · switch2 properties1 actions
Right switch
#3 · switch
Properties
Right switch
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Mode
#2 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Wired And Wireless1Wireless
Actions
Toggle
#1 · toggle
Switch Sensor#4 · switch-sensor1 properties3 events
Switch Sensor
#4 · switch-sensor
Properties
Mode
#1 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Multiple Click1Quick Single Click
Events
Click
#1 · click
Double Click
#2 · double-click
Long Press
#3 · long-press
Switch Sensor#5 · switch-sensor3 events
Switch Sensor
#5 · switch-sensor
Events
Click
#1 · click
Double Click
#2 · double-click
Long Press
#3 · long-press
Countdown#6 · countdown1 properties
Countdown
#6 · countdown
Properties
Countdown Time
#1 · countdown-time
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 1440, step 1 minutes
Countdown#7 · countdown1 properties
Countdown
#7 · countdown
Properties
Countdown Time
#1 · countdown-time
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 1440, step 1 minutes
Left click delay milliseconds#8 · jog-delay-time1 properties
Left click delay milliseconds
#8 · jog-delay-time
Properties
Keystroke delay milliseconds, 1 on, 0 off
#1 · jog-delay-time
- Format
- uint16
- Access
- R / W / N
- Value
- 0 ~ 65535, step 1
Right click delay in milliseconds#9 · jog-delay-time1 properties
Right click delay in milliseconds
#9 · jog-delay-time
Properties
Keystroke delay milliseconds, 1 on, 0 off
#1 · jog-delay-time
- Format
- uint16
- Access
- R / W / N
- Value
- 0 ~ 65535, step 1
The left button corresponds to the relay number#10 · switch-relay1 properties
The left button corresponds to the relay number
#10 · switch-relay
Properties
The key corresponds to the relay number
#1 · switch-relay
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 3, step 1
Right-click the relay number#11 · switch-relay1 properties
Right-click the relay number
#11 · switch-relay
Properties
The key corresponds to the relay number
#1 · switch-relay
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 3, step 1
The default state after left-clicking power on#12 · default-state1 properties
The default state after left-clicking power on
#12 · default-state
Properties
The default status after power on
#1 · default-state
- Format
- uint8
- Access
- R / W / N
- Value
- 0On1Off2Restore
Default state after power is powered on by the right button#13 · default-state1 properties
Default state after power is powered on by the right button
#13 · default-state
Properties
The default status after power on
#1 · default-state
- Format
- uint8
- Access
- R / W / N
- Value
- 0On1Off2Restore
Button backlight mode#15 · backlight-when-off2 properties
Button backlight mode
#15 · backlight-when-off
Properties
Left button backlight mode
#1 · backlight-mode-i
- Format
- uint8
- Access
- R / W / N
- Value
- 0Off1On2Blink
Right click backlight mode
#2 · backlight-mode-ii
- Format
- uint8
- Access
- R / W / N
- Value
- 0On1Off2Blink
Equipment on-line mark#16 · online-counter1 properties
Equipment on-line mark
#16 · online-counter
Properties
Device on-line identification, each time online, the counter increases by 1
#1 · online-counter
- Format
- uint32
- Access
- W / N
- Value
- 0 ~ 4294967295, step 1
Key interlock#17 · inter-lock1 properties
Key interlock
#17 · inter-lock
Properties
Key interlock
#1 · inter-lock
- Format
- bool
- Access
- R / W / N
- Value
- —
Mutual control allowed, release allowed#18 · mutual-control2 properties
Mutual control allowed, release allowed
#18 · mutual-control
Properties
One key mutual control allows, control allows
#1 · mutual-control-i
- Format
- bool
- Access
- W
- Value
- —
Two key mutual control allowed, control allowed
#2 · mutual-control-ii
- Format
- bool
- Access
- W
- Value
- —
Left click remote control binding table#19 · switch-panel11 properties
Left click remote control binding table
#19 · switch-panel
Properties
Remote control 1 MAC address 4 bytes
#1 · panel-mac-a
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 2 MAC address 4 bytes
#2 · panel-mac-b
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 3 MAC address 4 bytes
#3 · panel-mac-c
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 4 MAC address 4 bytes
#4 · panel-mac-d
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 5 MAC address 4 bytes
#5 · panel-mac-e
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 6 MAC address 4 bytes
#6 · panel-mac-f
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 7 MAC address 4 bytes
#7 · panel-mac-g
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 8 MAC address 4 bytes
#8 · panel-mac-h
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 9 MAC address 4 bytes
#9 · panel-mac-i
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 10 MAC address 4 bytes
#10 · panel-mac-j
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 11 MAC address 4 bytes
#11 · panel-mac-k
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Right-click the remote control binding table#20 · switch-panel11 properties
Right-click the remote control binding table
#20 · switch-panel
Properties
Remote control 1 MAC address 4 bytes
#1 · panel-mac-a
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 2 MAC address 4 bytes
#2 · panel-mac-b
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 3 MAC address 4 bytes
#3 · panel-mac-c
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 4 MAC address 4 bytes
#4 · panel-mac-d
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 5 MAC address 4 bytes
#5 · panel-mac-e
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 6 MAC address 4 bytes
#6 · panel-mac-f
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 7 MAC address 4 bytes
#7 · panel-mac-g
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 8 MAC address 4 bytes
#8 · panel-mac-h
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 9 MAC address 4 bytes
#9 · panel-mac-i
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 10 MAC address 4 bytes
#10 · panel-mac-j
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Remote control 11 MAC address 4 bytes
#11 · panel-mac-k
- Format
- uint32
- Access
- R / W / N
- Value
- 0 ~ 4294967295, step 1
Press to enter remote binding#21 · panel-add-enable2 properties
Press to enter remote binding
#21 · panel-add-enable
Properties
Left click to enter the remote binding state
#1 · panel-add-enable-a
- Format
- bool
- Access
- R / W / N
- Value
- —
Right-click to enter the remote binding state
#2 · panel-add-enable-b
- Format
- bool
- Access
- R / W / N
- Value
- —
Press to enter smart switch mode#22 · flexible-mode2 properties
Press to enter smart switch mode
#22 · flexible-mode
Properties
Left click to enter smart switch mode
#1 · flexible-mode-a
- Format
- bool
- Access
- R / W / N
- Value
- —
Right-click to enter smart switch mode
#2 · flexible-mode-b
- Format
- bool
- Access
- R / W / N
- Value
- —