MIOT HomeMIOT Home
UZ窗帘电机
#topwit.curtain.rzct01

UZ窗帘电机

urn:miot-spec-v2:device:curtain:0000A00C:topwit-rzct01:1:0000C817
Language
Service tree
Curtain
#2 · curtain
7 properties2 actions

Properties

Motor Control
#1 · motor-control
Format
uint8
Access
W
Value
0Pause
1Open
2Close
Current Position
#2 · current-position
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Target Position
#3 · target-position
Format
uint8
Access
R / W / N
Value
0 ~ 100, step 1 percentage
Motor Reverse
#4 · motor-reverse
Format
bool
Access
R / W / N
Value
—
Speed Level
#5 · speed-level
Format
uint8
Access
R / W / N
Value
1Low
2Medium
3High
Enable Manual Draw Curtain
#6 · enable-manual-draw-curtain
Format
bool
Access
R / W / N
Value
—
Mode
#7 · mode
Format
uint8
Access
R / W / N
Value
0Normal
1CountDown
2WakeUp

Actions

Motor Calibrate
#1 · motor-calibrate
Motion State Toggle
#2 · motion-state-toggle
Local scene panel
#3 · scene-panel
8 properties

Properties

Remote control 1 MAC address
#1 · panel-a
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Remote control 2 MAC address
#2 · panel-b
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Remote control 3 MAC address
#3 · panel-c
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Remote control 4 MAC address
#4 · panel-d
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Remote control 5 MAC address
#5 · panel-e
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Remote control 6 MAC address
#6 · panel-f
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
The corresponding tag number of the remote control, each occupying 4 bits
#7 · panel-pos
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
Allow remote control binding/unbinding
#8 · panel-bind-enable
Format
bool
Access
W
Value
—
Custom Service
#4 · custom-service
7 properties

Properties

Device launch identification, with a counter increase of 1 for each launch
#1 · online-counter
Format
uint32
Access
W / N
Value
0 ~ 4294967295, step 1
Start percentage of wake-up mode
#2 · wake-start-percent
Format
uint8
Access
R / W / N
Value
0 ~ 100, step 1 percentage
Wake up mode duration (minutes)
#3 · wake-duration-min
Format
uint16
Access
R / W / N
Value
0 ~ 65535, step 1 minutes
Countdown mode (on/off)
#4 · count-down-type
Format
uint8
Access
R / W / N
Value
1Open
2Close
countdown
#5 · countdown-time
Format
uint16
Access
R / W / N
Value
0 ~ 1440, step 1 minutes
#11 · product-type
Format
uint8
Access
R / N
Value
0Motor Only
1Motor And Light
Curtain control status
#12 · curtain-ctrl-state
Format
uint8
Access
N
Value
0Pause
1Open
2Close