#sundu.heater.mdrlx
尚度智能室内加热器NPT-QNS2506MDR-LX
urn:miot-spec-v2:device:heater:0000A01A:sundu-mdrlx:1:0000D06E
Language
Service tree
heater#2 · heater4 properties1 actions
heater
#2 · heater
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Fault
#2 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No Faults1Fall2Over-temperature3NTC-open-circuit4NTC-short-circuit
Heat Level
#3 · heat-level
- Format
- uint8
- Access
- R / W / N
- Value
- 0Cold wind1High2Low
Target temperature
#4 · target-temperature
- Format
- uint8
- Access
- R / W / N
- Value
- 20 ~ 40, step 1
Actions
toggle
#1 · toggle
Fan Control#4 · fan-control1 properties
Fan Control
#4 · fan-control
Properties
Horizontal Swing Switch Status
#1 · horizontal-swing
- Format
- bool
- Access
- R / W / N
- Value
- —
Environment#3 · environment1 properties
Environment
#3 · environment
Properties
Temperature
#1 · temperature
- Format
- uint8
- Access
- R / N
- Value
- 0 ~ 100, step 1 celsius
Custom Services#5 · custom5 properties
Custom Services
#5 · custom
Properties
Timing
#1 · timing
- Format
- uint8
- Access
- R / N / W
- Value
- 0 ~ 12, step 1 hours
Energy saving switch
#2 · eco
- Format
- bool
- Access
- R / N / W
- Value
- —
Humidify
#3 · humidification
- Format
- bool
- Access
- R / N / W
- Value
- —
Flame
#4 · flame
- Format
- bool
- Access
- R / N / W
- Value
- —
Current heating gear
#5 · current-gear
- Format
- uint8
- Access
- R / N
- Value
- 0Cold Wind1Strong Warmth2Weakly Warm