#sanmei.valve.s1
Eztofa智能重合闸通断器L2
urn:miot-spec-v2:device:electronic-valve:0000A0A7:sanmei-s1:1
Language
Service tree
Electronic Valve#2 · electronic-valve5 properties
Electronic Valve
#2 · electronic-valve
Properties
Valve Switch
#1 · valve-switch
- Format
- bool
- Access
- R / W / N
- Value
- —
Target Water Level
#2 · target-water-level
- Format
- uint8
- Access
- R / W / N
- Value
- 1Level1
Switch Status
#3 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Mode
#8 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Off1On
Device Fault
#5 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No Faults1GLGG2GW3GL4GY5QY6LD
Power Consumption#3 · power-consumption4 properties
Power Consumption
#3 · power-consumption
Properties
Power Consumption
#1 · power-consumption
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 99999999, step 1
Electric Current
#2 · electric-current
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 16777216, step 1
Voltage
#3 · voltage
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 65535, step 1
Electric Power
#6 · electric-power
- Format
- int32
- Access
- R / N
- Value
- 0 ~ 16777216, step 1 watt
Alarm Setting#4 · fault-setting12 properties
Alarm Setting
#4 · fault-setting
Properties
Overpower - The value is set
#1 · electric-alarm
- Format
- uint8
- Access
- R / N / W
- Value
- 1 ~ 26, step 1 watt
Setting the power overhigh alarm
#2 · electric-alarm-set
- Format
- bool
- Access
- W / N / R
- Value
- —
High temperature alarm - Threshold setting
#3 · high-temperature-set
- Format
- uint8
- Access
- R / N / W
- Value
- 40 ~ 150, step 1 celsius
High Temperature Alarm Setting
#4 · temperature-alarm
- Format
- bool
- Access
- R / W / N
- Value
- —
Overcurrent alarm - Threshold setting
#5 · overcurrent-alarm
- Format
- uint8
- Access
- R / N / W
- Value
- 1 ~ 63, step 1 A
Setting the overcurrent alarm
#6 · overcurrent-set
- Format
- bool
- Access
- R / W / N
- Value
- —
Overvoltage alarm - Threshold setting
#7 · overvoltage-alarm
- Format
- uint16
- Access
- R / N / W
- Value
- 220 ~ 300, step 1 V
Setting an overvoltage alarm
#8 · overvoltage-set
- Format
- bool
- Access
- W / R / N
- Value
- —
Undervoltage alarm - Min Value setting
#9 · undervoltage-alarm
- Format
- uint8
- Access
- W / N / R
- Value
- 70 ~ 220, step 1 V
Setting the undervoltage alarm
#10 · undervoltage-set
- Format
- bool
- Access
- W / R / N
- Value
- —
Leakage alarm - Threshold setting
#12 · eakage-alarm
- Format
- uint8
- Access
- R / N / W
- Value
- 10 ~ 100, step 1 mA
Set the leakage alarm
#13 · electric-leakage-set
- Format
- bool
- Access
- W / R / N
- Value
- —
user-defined#5 · custom7 properties1 actions
user-defined
#5 · custom
Properties
Display switch
#1 · display-switch
- Format
- bool
- Access
- R / W / N
- Value
- —
child lock
#2 · child-lock
- Format
- bool
- Access
- R / N / W
- Value
- —
Leakage protection function self-test
#3 · leakage-protection
- Format
- bool
- Access
- R / N / W
- Value
- —
Buzzer mute switch
#4 · beep-switch
- Format
- bool
- Access
- R / N / W
- Value
- —
Leakage protection is periodically self-checked
#5 · set-time-protection
- Format
- string
- Access
- W / R / N
- Value
- —
#13 · temperature
- Format
- float
- Access
- R / N
- Value
- -20 ~ 100, step 1 celsius
#14 · loudiandianliu
- Format
- uint32
- Access
- R / N
- Value
- 0 ~ 999, step 1 mA
Actions
self-test
#1 · zijian