#sanmei.valve.s1

Eztofa智能重合闸通断器L2

urn:miot-spec-v2:device:electronic-valve:0000A0A7:sanmei-s1:1
Language
Service tree
Electronic Valve
#2 · electronic-valve
5 properties

Properties

Valve Switch
#1 · valve-switch
Format
bool
Access
R / W / N
Value
—
Target Water Level
#2 · target-water-level
Format
uint8
Access
R / W / N
Value
1Level1
Switch Status
#3 · on
Format
bool
Access
R / W / N
Value
—
Mode
#8 · mode
Format
uint8
Access
R / W / N
Value
0Off
1On
Device Fault
#5 · fault
Format
uint8
Access
R / N
Value
0No Faults
1GLGG
2GW
3GL
4GY
5QY
6LD
Power Consumption
#3 · power-consumption
4 properties

Properties

Power Consumption
#1 · power-consumption
Format
uint32
Access
R / N
Value
0 ~ 99999999, step 1
Electric Current
#2 · electric-current
Format
uint32
Access
R / N
Value
0 ~ 16777216, step 1
Voltage
#3 · voltage
Format
uint32
Access
R / N
Value
0 ~ 65535, step 1
Electric Power
#6 · electric-power
Format
int32
Access
R / N
Value
0 ~ 16777216, step 1 watt
Alarm Setting
#4 · fault-setting
12 properties

Properties

Overpower - The value is set
#1 · electric-alarm
Format
uint8
Access
R / N / W
Value
1 ~ 26, step 1 watt
Setting the power overhigh alarm
#2 · electric-alarm-set
Format
bool
Access
W / N / R
Value
—
High temperature alarm - Threshold setting
#3 · high-temperature-set
Format
uint8
Access
R / N / W
Value
40 ~ 150, step 1 celsius
High Temperature Alarm Setting
#4 · temperature-alarm
Format
bool
Access
R / W / N
Value
—
Overcurrent alarm - Threshold setting
#5 · overcurrent-alarm
Format
uint8
Access
R / N / W
Value
1 ~ 63, step 1 A
Setting the overcurrent alarm
#6 · overcurrent-set
Format
bool
Access
R / W / N
Value
—
Overvoltage alarm - Threshold setting
#7 · overvoltage-alarm
Format
uint16
Access
R / N / W
Value
220 ~ 300, step 1 V
Setting an overvoltage alarm
#8 · overvoltage-set
Format
bool
Access
W / R / N
Value
—
Undervoltage alarm - Min Value setting
#9 · undervoltage-alarm
Format
uint8
Access
W / N / R
Value
70 ~ 220, step 1 V
Setting the undervoltage alarm
#10 · undervoltage-set
Format
bool
Access
W / R / N
Value
—
Leakage alarm - Threshold setting
#12 · eakage-alarm
Format
uint8
Access
R / N / W
Value
10 ~ 100, step 1 mA
Set the leakage alarm
#13 · electric-leakage-set
Format
bool
Access
W / R / N
Value
—
user-defined
#5 · custom
7 properties1 actions

Properties

Display switch
#1 · display-switch
Format
bool
Access
R / W / N
Value
—
child lock
#2 · child-lock
Format
bool
Access
R / N / W
Value
—
Leakage protection function self-test
#3 · leakage-protection
Format
bool
Access
R / N / W
Value
—
Buzzer mute switch
#4 · beep-switch
Format
bool
Access
R / N / W
Value
—
Leakage protection is periodically self-checked
#5 · set-time-protection
Format
string
Access
W / R / N
Value
—
#13 · temperature
Format
float
Access
R / N
Value
-20 ~ 100, step 1 celsius
#14 · loudiandianliu
Format
uint32
Access
R / N
Value
0 ~ 999, step 1 mA

Actions

self-test
#1 · zijian