MIOT HomeMIOT Home
Roborock S8
#roborock.vacuum.a51

Roborock S8

urn:miot-spec-v2:device:vacuum:0000A006:roborock-a51:1
Language
Service tree
Vacuum
#2 · vacuum
4 properties5 actions

Properties

Status
#1 · status
Format
uint8
Access
R / N
Value
1Getting Info
2Sleeping
3Ready
5Cleaning
6Returning To Dock
7Remote Control
8Charging
10Pause
11Spot Clean
12Error
14Updating
15Returning To Dock
16Pin And Go
17Zone Cleaning
18Room Clean
26Going To Wash The Mop
22Emptying
23Washing
29Mapping
Error
#2 · fault
Format
uint8
Access
R / N
Value
0 ~ 255, step 1 none
Suction Power
#4 · mode
Format
uint8
Access
R / W / N
Value
101Quiet
102Balanced
103Turbo
104Max
105Gentle
106Custom
Room Id
#9 · room-ids
Format
string
Access
Value
—

Actions

Clean
#1 · start-sweep
Pause
#2 · stop-sweeping
Mop
#4 · start-mop
Vacuum And Mop
#5 · start-sweep-mop
Sweep Room
#6 · start-room-sweep
Input
#9Room Idstring
Battery
#3 · battery
1 properties1 actions

Properties

Battery
#1 · battery-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage

Actions

Dock
#1 · start-charge
Find My Robot
#6 · identify
1 actions

Actions

Find My Robot
#1 · identify
Main Brush
#9 · brush-cleaner
1 properties

Properties

Main Brush Usage
#2 · brush-life-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Side Brush
#10 · brush-cleaner
1 properties

Properties

Side Brush Usage
#2 · brush-life-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Filter
#11 · filter
1 properties

Properties

Filter Usage
#1 · filter-life-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Generic-Rpc
#7 · generic-rpc
2 properties1 actions

Properties

Generic-Rpc-Call
#1 · rpc-in
Format
string
Access
Value
—
Rpc-Out
#2 · rpc-out
Format
string
Access
Value
—

Actions

Generic-Rpc-Call
#1 · generic-rpc-call
Input
#1Generic-Rpc-Callstring
Output
#2Rpc-Outstring
Roborock-Vacuum
#8 · roborock-vacuum
4 properties21 events

Properties

Consumable-Id
#1 · consumable-id
Format
uint8
Access
Value
0 ~ 255, step 1 none
Failed-Reason
#2 · failed-reason
Format
uint8
Access
Value
0 ~ 255, step 1 none
Error-Code
#3 · error-code
Format
uint16
Access
Value
0 ~ 65535, step 1 none
Schedule Type
#4 · schedule-type
Format
uint8
Access
Value
1Vacuum
2Mop
3Vacuum And Mop

Events

Error
#1 · error
Arguments
#3Error-Codeuint16
Maintenance
#2 · consumable-reminder
Arguments
#1Consumable-Iduint8
Starting Scheduled
#3 · schedule-canceled
Arguments
#2Failed-Reasonuint8
Starting Scheduled Cleaning.
#4 · schedule-started
Arguments
#4Schedule Typeuint8
Finished Cleaning. Returning To Dock.
#6 · clean-completed
Empty The Dustbin.
#7 · bin-full
Low Battery. Returning To Dock And Will Continue To Clean From Where It Left Off.
#8 · low-power-back
Could Not Find The Dock. Returned To The Starting Point.
#9 · back-to-origin-succ
Could Not Find The Dock. Could Not Return To The Starting Point.
#10 · back-to-origin-fail
Docking Error. Clear Obstacles Around Dock And Clean Charging Contacts.
#11 · back-to-dock-nearby
Positioning Failed. Starting New Clean.
#19 · clean-with-new-map
Water Level Low. Refill The Water Tank And Clean The Mop If Necessary.
#20 · water-short-reminder
Returned To The Dock, Emptying The Dustbin.
#21 · charge-dust-collect
Unable To Reach A Target. Cleaning Uncompleted.
#25 · clean-failed
Unable To Reach A Target. Finished Cleaning.
#27 · clean-partial-done
Failed To Return The Dock. Unable To Wash The Mop
#29 · back-wash-fail-bar
Robot-Dock Communication Failed. Unable To Wash The Mop.
#30 · back-wash-fail-comm
Failed To The Locate The Dock.Unable To Wash The Mop
#31 · back-wash-fail-dock
Positioning Failed.
#35 · positioning-failed
sleep-long-notify
#36 · sleep-long-notify
low-power-notify