Device Fault
#3 · fault
Format
uint8
Access
R / N
Value
0No faults
1E0 Fault - Heating Water Circuit Fault
2E1 Fault - Ignition Failure / False Flame / Residual Flame
3E2 Fault - Thermostat Overheating
4E3 Fault - Air Pressure Fault
5E4 Fault - Water Pressure Fault
6E5 Fault - Gas Valve Fault
7E6 Fault - DHW Temperature Sensor Fault
8E7 Fault - Heating Water Temperature Sensor Fault
9E8 Fault - Heating Water Over-Temperature (≥90℃)
10E9 Fault - Freezing Fault (≤1℃)
11EA Fault - Gas Valve Leakage Fault
12EF Fault - Condensate Blockage Fault
13EB Fault - Flue Gas Temperature Sensor Fault
Target Temperature
#6 · target-temperature
Format
float
Access
R / W / N
Value
35 ~ 60, step 1 celsius
Mode
#4 · mode
Format
uint8
Access
R / W / N
Value
0Summer
1Winter
ECO
#21 · eco
Format
bool
Access
R / W / N
Value
—
Heating Temperature
#34 · heating-temperature
Format
float
Access
R / N
Value
-30 ~ 100, step 1 celsius
Heating Target Temperature
#35 · heating-target-temperature
Format
float
Access
R / W / N
Value
30 ~ 80, step 1 celsius
Temperature
#5 · temperature
Format
float
Access
R / N
Value
-30 ~ 100, step 1 celsius
Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Status
#2 · status
Format
uint8
Access
R / N
Value
0Off
1Idle
2Bath Heating
3Warm Heating
4Anti Freezing
Pump
#10 · pump
1 properties

Properties

Hydraulic Pressure
#6 · hydraulic-pressure
Format
float
Access
R / N
Value
0 ~ 10, step 0.1 bar
Device Status
#11 · device-status
1 properties

Properties

Mute
#3 · mute
Format
bool
Access
R / W / N
Value
—