MIOT HomeMIOT Home
米家冰箱Pro 双系统 十字平嵌508L
#midjd.fridge.bs32z

米家冰箱Pro 双系统 十字平嵌508L

urn:miot-spec-v2:device:fridge:0000A00F:midjd-bs32z:1:0000D01E
Language
Service tree
Fridge
#2 · fridge
3 properties

Properties

Device Fault
#1 · fault
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Custom
1Smart
2Super Cool
3Super Freeze
Door Not Close Remind
#3 · door-not-close-remind
Format
uint8
Access
R / N
Value
0None
1Some
Fridge
#3 · fridge-chamber
2 properties

Properties

Temperature
#1 · temperature
Format
int8
Access
R / N
Value
-50 ~ 100, step 1 celsius
Target Temperature
#2 · target-temperature
Format
int8
Access
R / W / N
Value
2 ~ 8, step 1 celsius
Freezer
#4 · fridge-chamber
3 properties

Properties

Temperature
#1 · temperature
Format
int8
Access
R / N
Value
-50 ~ 100, step 1 celsius
Target Temperature
#2 · target-temperature
Format
int8
Access
R / W / N
Value
-24 ~ -16, step 1 celsius
Quick Frozen Temperature
#3 · quick-frozen-temperature
Format
int8
Access
Value
-30 ~ -16, step 1 celsius
Change Cabin
#6 · fridge-chamber
2 properties

Properties

Mode
#3 · mode
Format
uint8
Access
R / W / N
Value
0Dried Foods
1Maternal-infant Products
2Zero Degree
Temperature
#1 · temperature
Format
int8
Access
R / N
Value
-50 ~ 100, step 1 celsius
fridge-reset
#7 · fridge-reset
1 actions

Actions

reset
#1 · reset
fridge-run-status
#10 · fridge-run-status
16 properties

Properties

#1 · defrost-status
Format
uint8
Access
N
Value
0Off
1On
defrost-temperature
#2 · defrost-temperature
Format
int8
Access
N
Value
-50 ~ 100, step 1 celsius
#3 · refrigerating-damper
Format
uint8
Access
N
Value
0Close
1Open
#4 · freezing-fan
Format
uint8
Access
N
Value
0 ~ 20, step 1
#5 · compressor-speed
Format
uint16
Access
N
Value
0 ~ 10000, step 1
#6 · condensation-fan
Format
uint8
Access
N
Value
0 ~ 20, step 1
#7 · change-damper
Format
uint8
Access
N
Value
0Close
1Open
#8 · mini-change-damper
Format
uint8
Access
N
Value
0Close
1Open
#9 · environment-temp
Format
int8
Access
N
Value
-50 ~ 100, step 1 celsius
#10 · environment-humidity
Format
uint8
Access
N
Value
0 ~ 100, step 1 percentage
#11 · door-status
Format
uint16
Access
Value
0 ~ 65535, step 1
#19 · ref-fan-level
Format
uint8
Access
N
Value
0 ~ 255, step 1
#37 · valve-status
Format
uint8
Access
N
Value
0 ~ 255, step 1
#42 · ref-odor-snr
Format
uint8
Access
N
Value
0 ~ 100, step 1
#43 · ref-def-snr
Format
int8
Access
N
Value
-50 ~ 100, step 1
#44 · fault-third-level
Format
uint32
Access
N
Value
0 ~ 4294967295, step 1