MIOT HomeMIOT Home
迈斯VRF空调控制器Mesh2.0
#maxi.airc.air08

迈斯VRF空调控制器Mesh2.0

urn:miot-spec-v2:device:air-conditioner:0000A004:maxi-air08:1:0000C81A
Language
Service tree
Air Conditioner
#2 · air-conditioner
3 properties

Properties

ON/OFF
#1 · on
Format
bool
Access
R / W / N
Value
—
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Auto
1Heat
2Cool
4Fan
8Dry
Setting temperature
#3 · target-temperature
Format
uint8
Access
R / W / N
Value
16 ~ 32, step 1 celsius
Environment
#5 · environment
1 properties

Properties

Temperature
#2 · temperature
Format
uint8
Access
R / N
Value
0 ~ 70, step 1 celsius
Fan Control
#8 · fan-control
1 properties

Properties

Fan Level
#2 · fan-level
Format
uint8
Access
R / W / N
Value
0Auto
1Low
2Medium
3High
Underfloor Heating
#4 · floor-heat
3 properties

Properties

ON/OFF
#1 · on
Format
bool
Access
R / W / N
Value
—
Target temperature
#2 · target-temp
Format
int8
Access
R / W / N
Value
0 ~ 55, step 1 celsius
current-temp
#3 · current-temp
Format
uint8
Access
R / N
Value
0 ~ 70, step 1 celsius
Other
#6 · other
16 properties

Properties

#1 · three-one-mode
Format
uint8
Access
R / W / N
Value
0 ~ 15, step 1
Upper temperature limit
#2 · aircond-temp-upper
Format
uint8
Access
R / W / N
Value
28 ~ 32, step 1
Lower temperature limit
#3 · aircond-temp-lower
Format
uint8
Access
R / W / N
Value
16 ~ 20, step 1
floorheat-temp-upper
#4 · floorheat-temp-upper
Format
uint8
Access
R / W / N
Value
25 ~ 55, step 1
floorheat-temp-lower
#5 · floorheat-temp-lower
Format
uint8
Access
R / W / N
Value
0 ~ 20, step 1
temp-correct
#6 · temp-correct
Format
int8
Access
R / W / N
Value
-10 ~ 10, step 1
humi-correct
#7 · humi-correct
Format
int8
Access
R / W / N
Value
-20 ~ 20, step 1
time-correct
#8 · time-correct
Format
uint32
Access
W
Value
1725152400 ~ 4294967295, step 1
screen-protect
#10 · screen-protect
Format
bool
Access
R / W / N
Value
—
#11 · group-addr
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1
#12 · in-out-addr
Format
uint16
Access
R / W / N
Value
0 ~ 65535, step 1
#13 · relaying-setting
Format
uint8
Access
R / W / N
Value
0 ~ 31, step 1
#14 · floor-water-onoff
Format
bool
Access
R / N
Value
—
#15 · air-water-onoff
Format
bool
Access
R / N
Value
—
#16 · auto-setting
Format
uint8
Access
R / W / N
Value
0 ~ 15, step 1
#17 · user-config
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
fresh-air
#3 · fresh-air
3 properties

Properties

#1 · on
Format
bool
Access
R / W / N
Value
—
mode
#3 · mode
Format
uint8
Access
R / W / N
Value
1AirExchange
2AirExtraction
wind
#4 · wind
Format
uint8
Access
R / W / N
Value
1Low
2Medium
3High
sk-cmd
#7 · sk-cmd
5 properties

Properties

#1 · sk-ch-cmd
Format
uint16
Access
W
Value
0 ~ 65535, step 1
#2 · remote-a
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
#3 · remote-b
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
#4 · remote-c
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1
#5 · remote-d
Format
uint32
Access
R / N
Value
0 ~ 4294967295, step 1