#lxzn.valve.02

LTP智能导轨式断路器1P-MESH

urn:miot-spec-v2:device:electronic-valve:0000A0A7:lxzn-02:1:0000C833
Language
Service tree
Switch
#2 · electronic-valve
3 properties

Properties

Switch
#1 · valve-switch
Format
bool
Access
R / W / N
Value
—
Device Fault
#5 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Over Power Alarm
2HT Alarm
3Over Current Alarm
4Overvoltage Alarm
5Undervoltage Alarm
Mode
#8 · mode
Format
uint8
Access
R / W / N
Value
0Off
1On
2Memery
Power Consumption
#3 · power-consumption
4 properties

Properties

Power Consumption
#1 · power-consumption
Format
uint32
Access
R / N
Value
0 ~ 99999999, step 1
Electric Current
#2 · electric-current
Format
uint32
Access
R / N
Value
0 ~ 16777216, step 1
Voltage
#3 · voltage
Format
uint32
Access
R / N
Value
0 ~ 65535, step 1
Electric Power
#6 · electric-power
Format
uint32
Access
R / N
Value
0 ~ 16777216, step 1 watt
Alarm setting
#4 · fault-setting
10 properties

Properties

Over Power Alarm-threshold setting
#1 · electric-alarm
Format
uint8
Access
R / W / N
Value
1 ~ 26, step 1 watt
Over Power Alarm-set
#2 · electric-alarm-set
Format
bool
Access
R / W / N
Value
—
HT Alarm-threshold setting
#3 · heat-alert
Format
uint8
Access
R / W / N
Value
40 ~ 150, step 1 celsius
HT Alarm-set
#4 · heat-alert-set
Format
bool
Access
R / W / N
Value
—
Over Current Alarm-threshold setting
#5 · overcurrent-alarm
Format
uint8
Access
R / W / N
Value
1 ~ 82, step 1 A
Over Current Alarm-set
#6 · overcurrent-set
Format
bool
Access
R / W / N
Value
—
Overvoltage Alarm-threshold setting
#7 · overvoltage-alarm
Format
uint16
Access
R / W / N
Value
220 ~ 265, step 1 V
Overvoltage Alarm-set
#8 · overvoltage-set
Format
bool
Access
R / W / N
Value
—
Undervoltage Alarm-threshold setting
#9 · undervoltage-alarm
Format
uint8
Access
R / W / N
Value
26 ~ 240, step 1 V
Undervoltage Alarm-set
#10 · undervoltage-set
Format
bool
Access
R / W / N
Value
—
Type
#5 · dev-type
3 properties

Properties

Measure
#1 · jiliang
Format
uint8
Access
R / N
Value
0No
1Have
Temperature
#2 · wendu
Format
uint8
Access
R / N
Value
0No
1Have
Temperature
#3 · template
Format
int8
Access
R / N
Value
-20 ~ 100, step 1 celsius