MIOT HomeMIOT Home
Wi-Fi智能通断器L1
#lxzn.switch.cbcsmj

Wi-Fi智能通断器L1

urn:miot-spec-v2:device:switch:0000A003:lxzn-cbcsmj:2:0000D00D
Version v2 v1
Language
Service tree
Switch
#2 · switch
4 properties1 actions

Properties

Switch
#1 · on
Format
bool
Access
R / W / N
Value
—
Device Fault
#5 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Over Power
2HT Alarm
3Over Current
4Overvoltage Alarm
5Undervoltage Alarm
Temperature
#6 · temperature
Format
float
Access
R / N
Value
-20 ~ 100, step 1 celsius
Default Power On State
#8 · default-power-on-state
Format
uint8
Access
R / W / N
Value
0Off
1On
2Default

Actions

Toggle
#1 · toggle
Power Consumption
#3 · power-consumption
4 properties

Properties

Power Consumption
#1 · power-consumption
Format
uint32
Access
R / N
Value
0 ~ 99999999, step 1 kWh
Electric Current
#2 · electric-current
Format
uint32
Access
R / N
Value
0 ~ 16777216, step 1
Voltage
#3 · voltage
Format
uint32
Access
R / N
Value
0 ~ 65535, step 1
Electric Power
#6 · electric-power
Format
int32
Access
R / N
Value
0 ~ 16777216, step 1 watt
Alarm setting
#4 · fault-setting
10 properties

Properties

Overpower - The value is set
#1 · electric-alarm
Format
uint8
Access
R / N / W
Value
1 ~ 26, step 1 watt
Setting the power overhigh alarm
#2 · electric-alarm-set
Format
bool
Access
R / N / W
Value
—
High temperature alarm - Threshold setting
#3 · heat-alert
Format
uint8
Access
R / N / W
Value
40 ~ 150, step 1 celsius
High temperature Alarm Setting
#4 · heat-alert-set
Format
bool
Access
R / N / W
Value
—
Overcurrent alarm - Threshold setting
#5 · overcurrent-alarm
Format
uint8
Access
R / N / W
Value
1 ~ 82, step 1 A
Setting the overcurrent alarm
#6 · overcurrent-set
Format
bool
Access
R / N / W
Value
—
Overvoltage alarm - Threshold setting
#7 · overvoltage-alarm
Format
uint16
Access
R / N / W
Value
220 ~ 265, step 1 V
Setting an overvoltage alarm
#8 · overvoltage-set
Format
bool
Access
R / N / W
Value
—
Undervoltage alarm - Min Value setting
#9 · undervoltage-alarm
Format
uint8
Access
R / N / W
Value
76 ~ 240, step 1 V
Setting the undervoltage alarm
#10 · undervoltage-set
Format
bool
Access
R / N / W
Value
—
Custom
#5 · custom
2 properties

Properties

Device type
#1 · device
Format
uint8
Access
R / N
Value
0NO
1Have
Device configuration information
#2 · device-config
Format
uint8
Access
N / R
Value
0NO
1HAVE