#linp.airrtc.th113
领普智能温控器TH1(两联供)
urn:miot-spec-v2:device:thermostat:0000A031:linp-th113:1
Language
Service tree
Thermostat#2 · thermostat7 properties
Thermostat
#2 · thermostat
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Status
#2 · status
- Format
- uint8
- Access
- R / N
- Value
- 0Idle1Heating2Cooling
Device Fault
#3 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No Faults1Abnormality Of Built-In Sensor2Abnormality Of External Sensor
Mode
#4 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Cooling1Ventilation2AC Heating3Floor Heating4AC & Floor
Temperature adjustment
#5 · target-temperature
- Format
- float
- Access
- R / W / N
- Value
- 5 ~ 35, step 0.5 celsius
Fan Level
#6 · fan-level
- Format
- uint8
- Access
- R / W / N
- Value
- 0Auto1Low2Medium3High
Temperature
#7 · temperature
- Format
- float
- Access
- R / N
- Value
- -9.9 ~ 99.9, step 0.1 celsius
Environment#3 · environment2 properties
Environment
#3 · environment
Properties
Relative Humidity
#1 · relative-humidity
- Format
- uint8
- Access
- R / N
- Value
- 0 ~ 100, step 1 percentage
Temperature
#7 · temperature
- Format
- float
- Access
- R / N
- Value
- -9.9 ~ 99.9, step 0.1 celsius
Physical Control Locked#5 · physical-controls-locked1 properties
Physical Control Locked
#5 · physical-controls-locked
Properties
Physical Control Locked
#1 · physical-controls-locked
- Format
- bool
- Access
- R / W / N
- Value
- —
Indicator Light#7 · indicator-light1 properties
Indicator Light
#7 · indicator-light
Properties
LCD Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —