MIOT HomeMIOT Home
零狗智能青春版温控器ST851
#linked.airrtc.st851

零狗智能青春版温控器ST851

urn:miot-spec-v2:device:thermostat:0000A031:linked-st851:1
Language
Service tree
Thermostat
#2 · thermostat
5 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Device Fault
#3 · fault
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1
Mode
#4 · mode
Format
uint8
Access
R / W / N
Value
0Cool
1Heat
Target Temperature
#5 · target-temperature
Format
float
Access
R / W / N
Value
5 ~ 35, step 0.5 celsius
Fan Level
#6 · fan-level
Format
uint8
Access
R / W / N
Value
0Auto
1Level1
2Level2
3Level3
4Level4
5Level5
Environment
#3 · environment
2 properties

Properties

Relative Humidity
#1 · relative-humidity
Format
float
Access
R / N
Value
0 ~ 100, step 1 percentage
Temperature
#5 · temperature
Format
float
Access
R / N
Value
-30 ~ 100, step 0.1 celsius
customized-parameter
#4 · customized-parameter
36 properties

Properties

model-selection
#1 · model-selection
Format
uint8
Access
R / W / N
Value
00
11
22
33
44
55
66
77
88
99
1010
1111
1212
1313
1414
1515
1616
1818
1919
user-mode-selection
#2 · user-mode-selection
Format
uint8
Access
R / N / W
Value
0Cool-air
1Radiant-cooling
2CoolAir-RadiantCooling
3Dehumidification
4Warm-air
5Radiant-heating
6WarmAir-RadiantHeating
7Ventilation
8Ceiling-cooling
9CeilingCooling-RadiantCooling
10Ceiling-heating
11CeilingHeating-RadiantHeating
12Cooling-RadiantCooling-Dehumidification
#3 · sleep-mode
Format
bool
Access
W / R / N
Value
—
#4 · heatingcooling-limit
Format
uint8
Access
R / N / W
Value
0HeatingCooling-available
1Cooling-only
2Heating-only
#5 · target-humidity
Format
uint8
Access
R / N / W
Value
40 ~ 75, step 1 percentage
#6 · filter-reminder
Format
bool
Access
R / N / W
Value
—
dry-contact-mode
#7 · dry-contact-mode
Format
uint8
Access
R / N / W
Value
00
11
22
33
44
55
66
77
fan-contact-mode
#8 · fan-contact-mode
Format
uint8
Access
R / N / W
Value
0DelayFifteenSecondsOFF-Exp-FanCoil-RadiantCooling
1Cooling-FanAlwaysON
2Cooling-IntermittentOperation
3DelayFifteenSecondsOFF
4Heating-FanAlwaysON
5CoolingHeating-FanAlwaysON
6Ouput-F-Eleven-AfterStartup
#9 · ceiling-valve-mode
Format
uint8
Access
R / N / W
Value
0Closed
1Intermittent
2Open
3Temperature-hold
4Off-or-Delay-three-minutes-off
5Cooling-temperature-hold
6Closed-when-ON
7Disabled
#10 · floor-valve-mode
Format
uint8
Access
R / N / W
Value
0Intermittent
1Open
2Heating-temperature-hold
3Cooling-temperature-hold
#11 · floorvalve-off-time
Format
uint8
Access
R / N / W
Value
5 ~ 60, step 1 minutes
#12 · floorvalve-on-time
Format
uint8
Access
R / N / W
Value
5 ~ 60, step 1 minutes
floorsurface-settemp
#13 · floorsurface-settemp
Format
float
Access
R / N / W
Value
15 ~ 50, step 0.5 celsius
filter-clean-period
#14 · filter-clean-period
Format
uint16
Access
R / N / W
Value
100 ~ 9990, step 10
#15 · restore-fan-total-t
Format
bool
Access
R / N / W
Value
—
#16 · dew-point-temp
Format
float
Access
N / R
Value
-30 ~ 100, step 0.1 celsius
#17 · ext-ntc-temp
Format
float
Access
R / N
Value
-30 ~ 100, step 0.1 celsius
#18 · fan-total-run-time
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1 hours
#19 · air-valve-total-time
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1 hours
#20 · flo-valve-total-time
Format
uint16
Access
N / R
Value
0 ~ 65535, step 1
#21 · first-ch-status
Format
uint8
Access
R / N
Value
0Abnormal
1Normal
#22 · second-ch-status
Format
uint8
Access
R / N
Value
0Normal
1Abnormal
#23 · relay-load-status
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1
#24 · dc-output-voltage
Format
float
Access
R / N
Value
0 ~ 10, step 0.1 V
setting-t-low-limit
#25 · setting-t-low-limit
Format
float
Access
R / N / W
Value
5 ~ 18, step 0.5 celsius
setting-t-up-limit
#26 · setting-t-up-limit
Format
float
Access
W / R / N
Value
19 ~ 35, step 0.5 celsius
ext-sensor-function
#27 · ext-sensor-function
Format
uint8
Access
R / N / W
Value
0None
1Surface-Temperature
2Replace-Built-in
3Dual-Temperature-Point-Control
#28 · homescreen-display
Format
uint8
Access
R / N / W
Value
0Internal-Temperature
1External-Temperature
2Dewpoint
3Set-Temperature
4TVOC
5PM2.5
#29 · sec-ext-temp-setp
Format
float
Access
R / N / W
Value
5 ~ 60, step 0.5 celsius
air-valve-anti-age
#30 · air-valve-anti-age
Format
uint8
Access
R / N / W
Value
0None
1SevenDays-Off
2OneDay-Off
3TwoDays-Off
4ThreeDays-Off
5FourDays-Off
6FiveDays-Off
7SixDays-Off
flo-valve-anti-age
#31 · flo-valve-anti-age
Format
uint8
Access
W / R / N
Value
0None
1SevenDays-Off
2OneDay-Off
3TwoDays-Off
4ThreeDays-Off
5FourDays-Off
6FiveDays-Off
7SixDays-Off
thermostat-alarm
#32 · thermostat-alarm
Format
uint16
Access
R / N
Value
0 ~ 65535, step 1
#36 · period-fan-on-time
Format
uint8
Access
R / N / W
Value
5 ~ 60, step 1 minutes
#37 · period-fan-off-time
Format
uint8
Access
R / N / W
Value
5 ~ 60, step 1 minutes
#38 · ceilvalve-off-time
Format
uint8
Access
R / N / W
Value
5 ~ 60, step 1 minutes
#39 · ceilvalve-on-time
Format
uint8
Access
R / N / W
Value
5 ~ 60, step 1 minutes