MIOT HomeMIOT Home
方舟鱼人体存在平板灯MP
#line.light.frzpbd

方舟鱼人体存在平板灯MP

urn:miot-spec-v2:device:light:0000A001:line-frzpbd:1:0000C801
Language
Service tree
Light
#2 · light
5 properties4 actions

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Brightness
#2 · brightness
Format
uint8
Access
R / W / N
Value
1 ~ 100, step 1 percentage
Mode
#7 · mode
Format
uint8
Access
R / W / N
Value
0None
1Read
2Computer
3Bright
4Night light
Default Power On State
#9 · default-power-on-state
Format
uint8
Access
R / W / N
Value
0Default
1Off
2On
Flex Switch
#12 · flex-switch
Format
bool
Access
R / W / N
Value
—

Actions

Toggle
#1 · toggle
Brightness Up
#2 · brightness-up
Brightness Down
#3 · brightness-down
Toggle Light Mode
#4 · toggle-light-mode
Delay
#3 · delay
1 properties

Properties

Delay Time
#2 · delay-time
Format
uint32
Access
R / W / N
Value
1 ~ 120, step 1 minutes
Occupancy Sensor
#4 · occupancy-sensor
6 properties

Properties

Occupancy Status
#1 · occupancy-status
Format
uint8
Access
R / N
Value
0No One
1Has One
2No Sensor
No One Determine Time
#2 · no-one-determine-time
Format
uint16
Access
R / W / N
Value
0 ~ 10000, step 1 seconds
Illumination
#5 · illumination
Format
uint16
Access
R / N
Value
0 ~ 10000, step 1 lux
Detection Distance
#6 · detection-distance
Format
uint8
Access
R / W / N
Value
0 ~ 255, step 1
No One Detection Sensitivity
#7 · no-one-detection-sensitivity
Format
uint8
Access
R / W / N
Value
1Low
2Standard
3High
4Custom
Has Someone Detection Sensitivity
#8 · has-someone-detection-sensitivity
Format
uint8
Access
R / W / N
Value
1Low
2Standard
3High
4Custom
Remote Control Management
#6 · remote-control-management
5 properties4 actions

Properties

Remote Control Addable
#1 · remote-control-addable
Format
bool
Access
R / W / N
Value
—
Remote Control List 1
#3 · remote-control-list
Format
int32
Access
R / N
Value
-2147483648 ~ 2147483647, step 1
Remote Control List 2
#4 · remote-control-list
Format
int32
Access
R / N
Value
-2147483648 ~ 2147483647, step 1
Remote Control List 3
#5 · remote-control-list
Format
int32
Access
R / N
Value
-2147483648 ~ 2147483647, step 1
Remote Control List 4
#6 · remote-control-list
Format
int32
Access
R / N
Value
-2147483648 ~ 2147483647, step 1

Actions

Delete Remote Control 1
#1 · delete-remote-control
Input
#3Remote Control List 1int32
Delete Remote Control 2
#2 · delete-remote-control
Input
#4Remote Control List 2int32
Delete Remote Control 3
#3 · delete-remote-control
Input
#5Remote Control List 3int32
Delete Remote Control 4
#4 · delete-remote-control
Input
#6Remote Control List 4int32
Default state
#5 · default
15 properties

Properties

Radar sensor switch
#1 · inductive-switch
Format
bool
Access
R / W / N
Value
—
Automatic sensor light switch
#2 · inductive-lighting
Format
bool
Access
R / W / N
Value
—
Automatically turn on the light to trigger the illuminance threshold
#3 · trigger-threshold
Format
uint8
Access
R / W / N
Value
1Darkness
2Darker
3Brighter
4Arbitrary
Sensing the light status
#4 · lighting-status
Format
uint16
Access
R / W / N
Value
0 ~ 65535, step 1
Distance bitmap
#5 · distance-bitmap
Format
uint16
Access
R / W / N
Value
0 ~ 65535, step 1
Spatial Learning Reporting
#11 · parameter-reset
Format
uint8
Access
R / N
Value
1Studying
2StudySucc
3StudyFail
Direct connection pairing
#12 · pairing
Format
uint8
Access
W
Value
1Dind
2Relieve
Direct connection control function - Someone
#13 · direct-mode
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Direct connection control function - unattended
#14 · direct-mode-b
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Report status obtained
#15 · get
Format
uint8
Access
W
Value
1Radar Sensing Page-1
2Remote Control
3Settings Page Function
4Radar Sensing Page-2
Gradient time setting
#16 · fade-time
Format
uint32
Access
R / W / N
Value
0 ~ 4294967295, step 1
Enter learning control
#17 · study-ctrl
Format
uint8
Access
W
Value
0Off
1On
Interactive binding ID
#18 · binding-id
Format
uint32
Access
W
Value
0 ~ 4294967295, step 1
Interactive binding id grouping
#19 · binding-group-id
Format
uint32
Access
W
Value
0 ~ 4294967295, step 1
Illuminance And Distance Bitmap Function Switch
#20 · distance-switch
Format
bool
Access
R / W / N
Value
—