#hyd.airer.pro
米家智能晾衣机Pro
urn:miot-spec-v2:device:airer:0000A00D:hyd-pro:1
Language
Service tree
Airer#2 · airer4 properties
Airer
#2 · airer
Properties
Device Fault
#1 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No Faults1Obstruction2Overloaded3Motor Error
Motor Control
#2 · motor-control
- Format
- uint8
- Access
- W
- Value
- 0Pause1Raise2Lower
Status
#4 · status
- Format
- uint8
- Access
- R / N
- Value
- 0Upper Position Stopped1Raise2Lower3Pause4Lower Position Stopped
Mode
#5 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Off1On
Light#3 · light2 properties1 actions
Light
#3 · light
Properties
Light
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Brightness
#3 · brightness
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 100, step 1 percentage
Actions
Toggle
#1 · toggle
Set Night Light Switch#4 · set-night-light12 properties5 actions2 events
Set Night Light Switch
#4 · set-night-light
Properties
Start Time
#1 · start-time-hour
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 23, step 1 hours
Start Time
#2 · start-time-min
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 59, step 1 minutes
End Time
#3 · end-time-hour
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 23, step 1 hours
End Time
#4 · end-time-min
- Format
- uint8
- Access
- R / W / N
- Value
- 0 ~ 59, step 1 minutes
Night Light Switch
#5 · nightlight-switch
- Format
- uint8
- Access
- R / W / N
- Value
- 0Off1On
Night Lamp Brightness
#6 · brightness
- Format
- uint8
- Access
- R / W / N
- Value
- 1 ~ 100, step 1 percentage
Upper Limit
#7 · upper-limit
- Format
- int8
- Access
- R / N
- Value
- 0 ~ 49, step 1 percentage
Lower Limit
#8 · lower-limit
- Format
- uint8
- Access
- R / N
- Value
- 51 ~ 100, step 1 percentage
Setting Position
#9 · set-position
- Format
- uint8
- Access
- R / N / W
- Value
- 0 ~ 100, step 1 percentage
Lighting Brightness
#10 · brightness
- Format
- uint8
- Access
- R / N / W
- Value
- 0 ~ 100, step 1 percentage
Current Position
#11 · current-position
- Format
- uint8
- Access
- R / N
- Value
- 0 ~ 100, step 1 percentage
motor-speed
#12 · motor-speed
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 65025, step 1
Actions
Rod Control Raise
#1 · motor-control-up
Rod Control Lower
#2 · motor-control-down
Rod Control Pause
#3 · motor-control-pause
Set Upper Limit
#4 · set-upper-limit
Set Lower Limit
#5 · set-lower-limit
Events
Position Report
#1 · position-report
Arguments
#11Current Positionuint8
Final Position Report
#2 · finalposition-report
Arguments
#11Current Positionuint8