#dmaker.derh.50l
米家智能除湿机 50L
urn:miot-spec-v2:device:dehumidifier:0000A02D:dmaker-50l:1
Language
Service tree
Dehumidifier#2 · dehumidifier4 properties
Dehumidifier
#2 · dehumidifier
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Device Fault
#2 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No Faults1Water Full Protection2Temperature And Humidity Sensor Failure3Copper Tube Temperature Fault4Inter Board Communication Failure5Filter Screen Cleaning Reminder6Defrost Status7Fan Fault8Compressor Overload Protection9Fluorine Deficiency Protection
Mode
#3 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Smart1Low Noise2Clothes Drying
Target Humidity
#5 · target-humidity
- Format
- uint8
- Access
- R / W / N
- Value
- 30 ~ 70, step 1 percentage
Environment#3 · environment2 properties
Environment
#3 · environment
Properties
Relative Humidity
#1 · relative-humidity
- Format
- uint8
- Access
- R / N
- Value
- 0 ~ 100, step 1 percentage
Temperature
#2 · temperature
- Format
- float
- Access
- R / N
- Value
- -30 ~ 100, step 0.1 celsius
Alarm#4 · alarm1 properties
Alarm
#4 · alarm
Properties
Alarm
#1 · alarm
- Format
- bool
- Access
- R / W / N
- Value
- —
Indicator Light#5 · indicator-light2 properties
Indicator Light
#5 · indicator-light
Properties
Switch Status
#1 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Mode
#2 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Close1Twilight2Light
Physical Control Locked#6 · physical-controls-locked1 properties
Physical Control Locked
#6 · physical-controls-locked
Properties
Physical Control Locked
#1 · physical-controls-locked
- Format
- bool
- Access
- R / W / N
- Value
- —
Custom Features#7 · dm-service8 properties3 actions1 events
Custom Features
#7 · dm-service
Properties
Timed Shutdown Time
#1 · off-delay-time
- Format
- uint16
- Access
- R / N / W
- Value
- 0 ~ 480, step 1 minutes
Shutdown Delay Fan Shutdown
#2 · dry-after-off
- Format
- bool
- Access
- R / N / W
- Value
- —
Remaining Drying Time
#3 · dry-left-time
- Format
- uint16
- Access
- R / N
- Value
- 0 ~ 2400, step 1 seconds
Whether The Machine Is Warming Up
#4 · is-warming-up
- Format
- bool
- Access
- R / N
- Value
- —
Anion Switch
#5 · anion
- Format
- bool
- Access
- R / N / W
- Value
- —
Uv Switch
#6 · uv
- Format
- bool
- Access
- W / R / N
- Value
- —
Shutdown Drainage
#7 · pump-after-off
- Format
- bool
- Access
- R / N / W
- Value
- —
Whether Connected To Drain Pipe
#8 · tube-on
- Format
- bool
- Access
- R / N
- Value
- —
Actions
Switching Machine
#1 · toggle
Cycle Switching Mode
#2 · loop-mode
Reset Strainer
#3 · reset-filter
Events
The Water Tank Is Full
#1 · tank-full