MIOT HomeMIOT Home
米家智能除湿机 50L
#dmaker.derh.50l

米家智能除湿机 50L

urn:miot-spec-v2:device:dehumidifier:0000A02D:dmaker-50l:1
Language
Service tree
Dehumidifier
#2 · dehumidifier
4 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Device Fault
#2 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Water Full Protection
2Temperature And Humidity Sensor Failure
3Copper Tube Temperature Fault
4Inter Board Communication Failure
5Filter Screen Cleaning Reminder
6Defrost Status
7Fan Fault
8Compressor Overload Protection
9Fluorine Deficiency Protection
Mode
#3 · mode
Format
uint8
Access
R / W / N
Value
0Smart
1Low Noise
2Clothes Drying
Target Humidity
#5 · target-humidity
Format
uint8
Access
R / W / N
Value
30 ~ 70, step 1 percentage
Environment
#3 · environment
2 properties

Properties

Relative Humidity
#1 · relative-humidity
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Temperature
#2 · temperature
Format
float
Access
R / N
Value
-30 ~ 100, step 0.1 celsius
Alarm
#4 · alarm
1 properties

Properties

Alarm
#1 · alarm
Format
bool
Access
R / W / N
Value
—
Indicator Light
#5 · indicator-light
2 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Close
1Twilight
2Light
Physical Control Locked
#6 · physical-controls-locked
1 properties

Properties

Physical Control Locked
#1 · physical-controls-locked
Format
bool
Access
R / W / N
Value
—
Custom Features
#7 · dm-service
8 properties3 actions1 events

Properties

Timed Shutdown Time
#1 · off-delay-time
Format
uint16
Access
R / N / W
Value
0 ~ 480, step 1 minutes
Shutdown Delay Fan Shutdown
#2 · dry-after-off
Format
bool
Access
R / N / W
Value
—
Remaining Drying Time
#3 · dry-left-time
Format
uint16
Access
R / N
Value
0 ~ 2400, step 1 seconds
Whether The Machine Is Warming Up
#4 · is-warming-up
Format
bool
Access
R / N
Value
—
Anion Switch
#5 · anion
Format
bool
Access
R / N / W
Value
—
Uv Switch
#6 · uv
Format
bool
Access
W / R / N
Value
—
Shutdown Drainage
#7 · pump-after-off
Format
bool
Access
R / N / W
Value
—
Whether Connected To Drain Pipe
#8 · tube-on
Format
bool
Access
R / N
Value
—

Actions

Switching Machine
#1 · toggle
Cycle Switching Mode
#2 · loop-mode
Reset Strainer
#3 · reset-filter

Events

The Water Tank Is Full
#1 · tank-full