MIOT HomeMIOT Home
三合一温控器SR-Mesh版
#bean.airrtc.nt01

三合一温控器SR-Mesh版

urn:miot-spec-v2:device:thermostat:0000A031:bean-nt01:1:0000C822
Language
Service tree
Air Conditioner
#2 · air-conditioner
4 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Auto
1Cool
2Heat
3Fan
4Dry
Device Fault
#3 · fault
Format
uint8
Access
R / N
Value
0No Faults
Target Temperature
#4 · target-temperature
Format
uint8
Access
R / W / N
Value
16 ~ 35, step 1 celsius
Air Fresh
#3 · air-fresh
4 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Device Fault
#2 · fault
Format
uint8
Access
R / N
Value
0No Faults
Mode
#3 · mode
Format
uint8
Access
R / W / N
Value
0Wind-in
1Wind-out
Fan Level
#4 · fan-level
Format
uint8
Access
R / W / N
Value
0Auto
2Low
3Medium
4High
Thermostat
#4 · thermostat
2 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Target Temperature
#2 · target-temperature
Format
uint8
Access
R / W / N
Value
16 ~ 32, step 1 celsius
Fan Control
#5 · fan-control
1 properties

Properties

Fan Level
#1 · fan-level
Format
uint8
Access
R / W / N
Value
0Auto
2Low
3Medium
4High
Environment
#6 · environment
2 properties

Properties

Relative Humidity
#1 · relative-humidity
Format
uint8
Access
R / N
Value
1 ~ 100, step 1 percentage
Temperature
#2 · temperature
Format
int16
Access
R / N
Value
-30 ~ 60, step 1 celsius
Settings
#7 · adv-setting
8 properties

Properties

Panel mode selection
#1 · three-one-mode
Format
uint8
Access
R / W / N
Value
0 ~ 15, step 1
Upper limit of AC TEMP
#2 · air-temp-up
Format
uint8
Access
R / W / N
Value
28 ~ 32, step 1
Lower limit of AC TEMP
#3 · air-temp-down
Format
uint8
Access
R / W / N
Value
16 ~ 20, step 1
Upper limit of UFH TEMP
#4 · hot-temp-up
Format
uint8
Access
R / W / N
Value
28 ~ 35, step 1
Lower limit of UFH TEMP
#5 · hot-temp-down
Format
uint8
Access
R / W / N
Value
16 ~ 20, step 1
TEMP sensor correction
#6 · temp-correct
Format
int8
Access
R / W / N
Value
-10 ~ 10, step 1
Humidity sensor correction
#7 · humi-correct
Format
int8
Access
R / W / N
Value
-20 ~ 20, step 1
Time proofreading
#8 · time-correct
Format
uint32
Access
W
Value
0 ~ 4294967295, step 1