urn:miot-spec-v2:device:bath-heater:0000A028:aupu-s2air:2
Version v2 v1
Language
Service tree
Light
#2 · light
1 properties

Properties

Lighting
#1 · on
Format
bool
Access
R / W / N
Value
—
PTC Bath Heater
#3 · ptc-bath-heater
3 properties

Properties

Device Fault
#1 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Temperature Module Fault
2Communication Fault
3Temperature Sensor And Communication Failure
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Idle
2Fan
4Dry
7Ventilation
18AI constant warmth
21Deodorize
Temperature regulation
#3 · target-temperature
Format
uint8
Access
R / W / N
Value
30 ~ 42, step 1 celsius
Environment
#4 · environment
1 properties

Properties

Temperature
#1 · temperature
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 celsius
Fan Control
#5 · fan-control
2 properties

Properties

Horizontal Swing
#1 · horizontal-swing
Format
uint8
Access
R / W / N
Value
2Swing
3Swing-stop
1Degrees90
0Close
4Degrees45
Fan Level
#2 · fan-level
Format
uint8
Access
R / W / N
Value
1 ~ 3, step 1
Extend
#6 · extend
16 properties

Properties

Left Time
#1 · left-time
Format
uint16
Access
R / N
Value
0 ~ 480, step 1 minutes
Lights
#3 · external-light
Format
bool
Access
R / N / W
Value
—
Night Light
#4 · night-light
Format
bool
Access
R / N / W
Value
—
Ventilation gear
#5 · ventilate-gear
Format
uint8
Access
R / N / W
Value
1 ~ 3, step 1
Intelligent human perception scene
#6 · set-duration
Format
string
Access
R / N / W
Value
—
Human sensory attribute settings
#7 · human-set
Format
uint8
Access
R / W / N
Value
0 ~ 255, step 1
Working hours
#8 · working-time
Format
uint16
Access
R / N
Value
0 ~ 480, step 1 minutes
Vacation mode
#9 · vacation-mode
Format
bool
Access
R / N / W
Value
—
Reserve a Warm Room
#10 · reservation-warm
Format
string
Access
N / W / R
Value
—
Local reservation
#11 · reservation-local
Format
string
Access
R / W / N
Value
—
Human perception standby
#12 · idle-induction
Format
bool
Access
R / W / N
Value
—
Reminder for reserving a warm room
#13 · warm-local-state
Format
uint8
Access
R / N / W
Value
0Off
1On
2Running15
3Stop
Human Feeling Night Light
#14 · human-night
Format
string
Access
R / N / W
Value
—
No one judges the time
#15 · noone-judge-time
Format
uint16
Access
R / W / N
Value
10 ~ 1800, step 10 seconds
Intelligent human perception scene disabled
#16 · inte-human-disable
Format
bool
Access
R / N
Value
—
#21 · match-version
Format
uint8
Access
W
Value
0 ~ 100, step 1