#aden.waterheater.ash200
VINO空气能热水器200L
urn:miot-spec-v2:device:water-heater:0000A02A:aden-ash200:1
Language
Service tree
Water Heater#2 · water-heater5 properties
Water Heater
#2 · water-heater
Properties
Device Fault
#1 · fault
- Format
- uint8
- Access
- R / N
- Value
- 0No Faults
Target Temperature
#2 · target-temperature
- Format
- float
- Access
- R / W / N
- Value
- 35 ~ 75, step 0.5 celsius
Temperature
#3 · temperature
- Format
- float
- Access
- R / N
- Value
- -100 ~ 100, step 0.1 celsius
Mode
#4 · mode
- Format
- uint8
- Access
- R / W / N
- Value
- 0Standard1Energy12Energy23Quick4ElectricHeating
Switch Status
#6 · on
- Format
- bool
- Access
- R / W / N
- Value
- —
Physical Control Locked#4 · physical-controls-locked1 properties
Physical Control Locked
#4 · physical-controls-locked
Properties
Physical Control Locked
#1 · physical-controls-locked
- Format
- bool
- Access
- R / W / N
- Value
- —
CustomService#7 · custom-service17 properties
CustomService
#7 · custom-service
Properties
AppointTimeOne
#1 · appoint-time-one
- Format
- uint16
- Access
- R / N / W
- Value
- 0 ~ 1439, step 1 seconds
AppointTimeOneOn
#2 · appoint-time-one-on
- Format
- bool
- Access
- R / N / W
- Value
- —
AppointTimeTwo
#3 · appoint-time-two
- Format
- uint16
- Access
- R / N / W
- Value
- 0 ~ 1439, step 1 seconds
AppointTimeTwoOn
#4 · appoint-time-two-on
- Format
- bool
- Access
- R / N / W
- Value
- —
SterilizeCycle
#5 · sterilize-cycle
- Format
- uint8
- Access
- R / N / W
- Value
- 0 ~ 30, step 1 days
SterilizeTime
#6 · sterilize-time
- Format
- uint16
- Access
- R / N / W
- Value
- 0 ~ 1439, step 1 seconds
SterilizeTemperature
#7 · sterilize-temp
- Format
- float
- Access
- R / N / W
- Value
- 60 ~ 75, step 0.5 celsius
VacationStartDate
#8 · vacation-start-date
- Format
- uint32
- Access
- R / N / W
- Value
- 20000101 ~ 29991231, step 1
VacationEndDate
#9 · vacation-end-date
- Format
- uint32
- Access
- R / N / W
- Value
- 20000101 ~ 29991231, step 1
IncreaseCapacity
#10 · increase-capacity
- Format
- float
- Access
- R / N / W
- Value
- 60 ~ 75, step 0.5 celsius
IncreaseCapacityOn
#11 · increase-capacity-on
- Format
- bool
- Access
- R / N / W
- Value
- —
SterilizeOn
#12 · sterilize-on
- Format
- bool
- Access
- R / N / W
- Value
- —
VacationOn
#13 · vacation-on
- Format
- bool
- Access
- R / N / W
- Value
- —
appoint-one-mode
#14 · appoint-one-mode
- Format
- uint8
- Access
- R / N / W
- Value
- 0Standard1Energy12Energy23Quick4ElectricHeating
#15 · appoint-one-temp
- Format
- float
- Access
- R / N / W
- Value
- 35 ~ 75, step 0.5 celsius
appoint-two-mode
#16 · appoint-two-mode
- Format
- uint8
- Access
- R / N / W
- Value
- 0Standard1Energy12Energy23Quick4ElectricHeating
#17 · appoint-two-temp
- Format
- float
- Access
- R / N / W
- Value
- 35 ~ 75, step 0.5 celsius